EasyManua.ls Logo

Parker IPA-15HC - Troubleshooting IPA Motor Control

Parker IPA-15HC
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
68 IPA Hardware Installation Guide
Motor Control
The first step in troubleshooting motor-control issues is to examine the Drive/Controller Status LEDs (Figure 32).
Use the following table to determine the indicated condition. Use the additional information in this section to take
corrective action. On power-up, the LED pattern will flash through the various boot stages before settling into one
of the patterns listed below.
Figure 32. - Drive/Controller Status LEDs
Drive Status Indicator LED Descriptions
Controller Status LED Illumination States
LED Middle
LED Top
Description
Drive/Controller Enabled
Off
Green
Enabled
Yellow (flashes during Regeneration)
Green
Enabled, Regeneration active
Yellow/Green (alternating)
Green
Enabled, Autorun mode
Drive/Controller Disabled
Off
Red
Disabled, no faults
Yellow
Red
Disabled, no bridge power
Yellow & 1 Green (flashing)
Red
Disabled, Bridge fault
Yellow & 2 Green (flashing)
Red
Disabled, Feedback fault (Hall error or Encoder loss)
Yellow & 3 Green (flashing)
Red
Disabled, Thermal fault
Yellow & 4 Green (flashing)
Red
Disabled, other fault (Undervoltage, Overvoltage,
Motor Configuration error, Motor Regeneration
fault, or Network Loss fault)
Yellow & 5 Green (flashing)
Red
Disabled, Drive Parameter fault
Green
Red
Hardware watchdog fault
*Ethernet LED will also be Red
N/A
Orange
Flash is being modified.
Ethernet Network
Status
Drive/Controller
Status

Table of Contents

Related product manuals