Effective: December, 2014
Document Number: 88-032500-01A
IPA Intelligent Parker Amplifier
Hardware Installation Guide

Table of Contents

Questions and Answers

  • J
    Julie KnoxAug 17, 2025
    What to do if the Parker Controller shows a 'Continuous Current = 0' error?
    • R
      Ronald MckinneyAug 17, 2025
      To correct the error with the Parker Controller, you must set a non-zero value for continuous current. Refer to your motor specifications for the correct value (C1 Continuous Current).
  • A
    amylewisAug 20, 2025
    How to fix 'Resistance = 0' error on Parker IPA04-HC Controller?
    • H
      Holly ReyesAug 20, 2025
      To fix the issue, set a non-zero value for motor winding resistance in your Parker Controller settings. Refer to your motor specifications for the correct value (C7 Motor Winding Resistance).
  • W
    William SmithAug 22, 2025
    How to resolve 'Rated Speed = 0' error on Parker Controller?
    • E
      Erica HillAug 23, 2025
      To resolve the 'Rated Speed = 0' error on your Parker Controller, you need to set a non-zero value for the motor rated speed. Please refer to your motor specifications for the correct value (C8 Motor Rated Speed).
  • A
    Alexander ThompsonAug 26, 2025
    How do I fix the 'Max Inductance = 0' error on my Parker IPA04-HC?
    • R
      Richard RuizAug 26, 2025
      To fix the 'Max Inductance = 0' error on your Parker Controller, you must set a non-zero value. Refer to your motor specifications for the correct value (C4 Motor Inductance).
  • J
    Jamie ClarkeAug 28, 2025
    How to fix the 'Ke = 0' error on a Parker Controller?
    • M
      Megan WilliamsAug 28, 2025
      To correct the 'Ke = 0' error for your Parker Controller, set a non-zero value. Refer to your motor specifications for the correct value (C15 Motor Ke).
  • A
    annettemcleanAug 31, 2025
    Why is the Ethernet Network Status LED off on my Parker IPA04-HC Controller?
    • J
      Justin BlankenshipAug 31, 2025
      If the Ethernet Network Status LED is off on your Parker Controller, verify that no two drive/controllers on the network have the same IP address. The IP address is determined by the Address Switch settings on the front panel of the unit. Also, using a standard Ethernet connection, test the IP assignment. At a DOS or command prompt, type 'ping 192.168.100.xx', where xx is the setting of the IPA address switches on the front panel. If you see a 'timeout' message, then the unit is properly configured and is network accessible. Re-attach the Ethernet cable. If a 'timeout' message is seen, the IPA has an invalid IP address. Change the address switches to the correct address and cycle power.
  • S
    sandersmarySep 2, 2025
    What does 'Motor Configuration Warning' mean on my Parker IPA04-HC?
    • D
      Douglas WadeSep 2, 2025
      If you receive a Motor Configuration Warning on your Parker Controller, it means the motor rating is too high for the drive/controller, and the drive/controller is using its own limits for safety reasons.
  • J
    Joshua WilliamsSep 5, 2025
    What to do if I see a 'Motor Configuration Error' on my Parker Controller?
    • L
      Luis SchwartzSep 5, 2025
      If you get a Motor Configuration Error on your Parker Controller, it means that one of the motor parameters is set to zero (0). Look at the additional errors to find which parameters are set at zero (0). Refer to your motor specifications for the correct value.
  • T
    Terry LarsonSep 12, 2025
    How to prevent noise on Hall signals in Parker IPA04-HC?
    • N
      Nichole HensonSep 12, 2025
      If you encounter noise on the Hall signals in your Parker Controller setup, keep high power cables away from low power cables (such as the feedback cable). If they need to cross, cross at right angles.
  • C
    Casey ColonSep 13, 2025
    Why are neither RJ-45 Ethernet Status LEDs illuminated on my Parker IPA04-HC?
    • R
      rmatthewsSep 13, 2025
      If neither RJ-45 Ethernet Status LED is illuminated on your Parker Controller, verify that you are using the correct type of cable. Verify that the cable pinout matches the drive’s connector pin out. Try swapping cables with Ethernet cables you know to be good. Even cables that do not meet the Ethernet cable specification should cause the LEDs to illuminate. If the LEDs still do not illuminate, look for Ethernet hardware problems.

Summary

Important Safety Information

Mechanical Installation

Electrical Installation

Installation Safety Requirements

Outlines safety requirements for IPA installation per LVD and EMC directives.

Power Supply

Explains power supply options and requirements for the IPA.

Earth Ground

Emphasizes the importance of proper earth ground connection.

Safety Earth Connection

Recommends a star safety earth configuration for multiple drives.

Communications

Assigning IP Addresses

Guides on setting IP addresses for IPA and PC.

Setting the IP Address- IPA

Details how to set the IPA's IP address using rotary switches.

Setting the IP Address and Subnet Mask-PC

Explains how to configure the PC's IP address and subnet mask.

Troubleshooting

General Troubleshooting Guidelines

Provides general guidelines for troubleshooting IPA issues.

Power

Guides troubleshooting power-related issues, checking LEDs.

Communications

Details troubleshooting communication problems, focusing on Ethernet.

RJ-45 Ethernet Status LEDs

Explains how to interpret RJ-45 Ethernet status LEDs.

Ethernet Network Status LED

Describes the Ethernet Network Status LED and its meanings.

Motor Control

Guides troubleshooting motor control issues using status LEDs.

Fault Correction

Explains how to access and correct drive errors using ACR-View.

Error Codes

Lists error codes and their resolutions for troubleshooting.

Hall Sensors

Provides troubleshooting procedures for Hall sensor faults.

Troubleshooting Checklist

Offers a checklist to identify Hall fault causes.

Possible Problems

Lists common problems related to Hall sensor faults.

Procedures

Outlines procedures for fixing motor wire and Hall wire issues.

Torque Enable Safety Circuitry

Torque Enable Functional Description

Explains the dual-channel hardware implementation of Torque Enable.

User Connections

Details the connections for Torque Enable terminals on the Auxiliary connector.

Torque Enable Technical Specification

Lists the input specifications for the Torque Enable function.

Fault Operation

Details how faults are detected when enable signals are opposite.

Additional Specifications

Short Circuit Protection

Explains the drive's protection against short circuits.

Resetting the fault

Describes methods to clear a latched fault after protection activation.

Drive;Controller Over-Temperature Protection

Details the over-temperature protection mechanism and reset.

Under-Voltage Protection

Explains the under-voltage protection and its results.

Over-Voltage Protection

Describes over-voltage protection against excessive regeneration.

Current Foldback

Details the current foldback circuit for unit protection.

Regulatory Compliance UL and CE

General Safety Considerations

Safety recommendations for installation per local authorities.

General EMC Considerations

Recommendations for meeting EMC directive requirements.

Installing the IPA Drive

Guidance for qualified technicians on installing the IPA drive.

A Safe Installation - Meeting the Requirements of the Low Voltage Directive (LVD)

Measures for safe installation compliant with the Low Voltage Directive.

APPENDIX B IPA with IForce or Ripped Linear Servos

IPA Thermal Model Protection and Power Installation

Explains thermal model protection and power installation practices.

Software Configuration: Set Feedback Resolution

Details setting encoder feedback resolution in ACR-View.

Software Configuration: Position Error & Soft Limits

Covers setting position error and soft limits in ACR-View.

Parker IPA04-HC Specifications

General IconGeneral
ModelIPA04-HC
TypeController
Input Voltage24V DC
Output Current4A
Continuous Current4A
Peak Current8A
Maximum Current8A
Supply Voltage24V DC
Input Signal4-20mA
Hysteresis1%
Protection FeaturesShort circuit, over temperature
Storage Temperature-20°C to +70°C
Weight500g

Related product manuals