ADDITIONAL SPECIFICATIONS
IPA Hardware Installation Guide 89
Figure 35. - Time Until Current Foldback Occurs
Cables
EMC Ready Cables
Many Parker cables are EMC installation ready. If installed according to instructions provided under A Highly-
Immune, Low-Emission Installation Meeting the Requirements of the Electromagnetic Compatibility (EMC)
Directiveon page 93, these cables are designed to aid the user in gaining European Compliance, and are thus an
integral part of a CE system solution. EMC cables add RF screening and bonding to reduce emissions, increase
immunity, and provide high integrity safety Earth bonding. They also help to reduce problems in high electrical
noise environments.
Non-EMC Cables
Parker also offers non-EMC cables, for applications where CE compliance is not required, and where ambient
electrical noise does not cause problems. Because these cables are either unshielded, or contain simple foil
shielding terminated by a drain wire, they do not provide significant shielding of electrical noise at high frequencies.