APPENDIX B
IPA Hardware Installation Guide 113
Software Configuration: End of Travel (EOT)
Limits & Home
Select the on-board input for positive limit. The Negative Limit will be the next input and the home the following.
Note that for IForce and Ripped positioners, the home sensors are normally closed; change this screen’s default
from Normally Open (NO) to Normally Closed (NC).