Programming
Page D-168 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
PREF Name Block Type Range Default ro\rw Notes
50.05 IGNORE PASSWORD OPERATOR MENU 18 BOOL 0 : FALSE
1 : TRUE
FALSE rw
51.01 PARAMETER OPERATOR MENU 19 PREF 00.00 to A3.05 0 rw
51.02 NAME OPERATOR MENU 19 STRING max length is 16 chars rw
51.03 SCALING OPERATOR MENU 19 ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw
51.04 READ ONLY OPERATOR MENU 19 BOOL 0 : FALSE
1 : TRUE
FALSE rw
51.05 IGNORE PASSWORD OPERATOR MENU 19 BOOL 0 : FALSE
1 : TRUE
FALSE rw
52.01 PARAMETER OPERATOR MENU 20 PREF 00.00 to A3.05 0 rw
52.02 NAME OPERATOR MENU 20 STRING max length is 16 chars rw
52.03 SCALING OPERATOR MENU 20 ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw
52.04 READ ONLY OPERATOR MENU 20 BOOL 0 : FALSE
1 : TRUE
FALSE rw
52.05 IGNORE PASSWORD OPERATOR MENU 20 BOOL 0 : FALSE
1 : TRUE
FALSE rw
53.01 PARAMETER OPERATOR MENU 21 PREF 00.00 to A3.05 0 rw
53.02 NAME OPERATOR MENU 21 STRING max length is 16 chars rw

Table of Contents