HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • R
    Robert HernandezAug 19, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • K
      Kathleen HunterAug 19, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • J
    john37Aug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • K
      Kyle AguilarAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • T
    Timothy BurtonAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • T
      trobinsonAug 26, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • K
    Kristen HendersonAug 28, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • S
      Stephanie DrakeAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • R
    Richard NelsonAug 30, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • W
      william70Aug 30, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • M
    Matthew FullerSep 2, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • M
      Miguel HamptonSep 2, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • R
    Ronald KimSep 4, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • K
      Kevin RogersSep 4, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • A
    Andrew GibsonSep 6, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • D
      Dana MosesSep 6, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • A
    April IngramSep 9, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • S
      Steven CrawfordSep 9, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • D
    denisebennettSep 12, 2025
    What causes Parker Dehumidifier failure to switch?
    • S
      shannoncarpenterSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

Inspection and Handling

Inspect unit upon arrival for damage, report issues to carrier and service department.

Safety and System Precautions

General Safety Warnings

Use caution, relieve pressure, disconnect power before servicing, wear PPE.

System Component Safety

Handle drain valves and condensate carefully; note safety relief valve function.

Sequence of Operation

Solenoid Valve Functions

Details the role of five solenoids in managing inlet, exhaust, and repressurization.

Operational Cycle Steps

Explains the sequence of tower drying, repressurization, and regeneration.

Start Up Procedure

Pre-Operation Checks

Verify wiring, power, control air isolation; ensure compressor is running.

System Energization

Energize electrical circuit, check purge settings, operate without mufflers initially.

Shutdown Procedures

Dryer Isolation Steps

Steps to isolate the dryer by removing power and closing valves.

Demand Cycles

Cycle Loc Operation

Standard feature for compressor-interfaced load adjustment and cycle pausing.

Pro Purge System

Advanced proportional control using dew point monitoring for efficiency.

Powerloc Dew Point Monitor

Digital monitor that adjusts cycles based on dew point for energy savings.

Maintenance Program

Daily Maintenance Tasks

Check dew point, purge flow, gauges, and auto drain operation.

Desiccant Replacement

Inlet and Exhaust Valve Repair

Troubleshooting Guide

Dryer Not Operating Issues

Diagnosing problems like no power, blown fuses, or controller failures.

Cycle Failure Troubleshooting

Addressing issues related to the dryer not switching or cycling correctly.

Outlet Dew Point Problems

Identifying causes for high dew points, including purge rate and desiccant condition.

Air Loss and Leakage

Troubleshooting excessive air loss and leaks in valves or solenoids.

Wiring Diagrams

Analyzing Chart

PowerLoc System