HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • C
    Cheryl JacksonAug 19, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • A
      Aaron RiceSep 12, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • L
    Lauren GarrisonAug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • C
      Christopher KellyAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • M
    Michelle PattersonAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • S
      Shelley BarberAug 27, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • E
    evansrachelAug 28, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • A
      Amanda JimenezAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • J
    Jerry AndersonAug 30, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • A
      Angela JacobsAug 31, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • K
    Kathryn JohnsonSep 2, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • E
      ethan63Sep 2, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • V
    Victoria GilmoreSep 4, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • S
      Sean WilliamsonSep 4, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • K
    Kristin Wells MDSep 6, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • D
      Donna RodriguezSep 6, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • P
    parkerandrewSep 9, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • D
      Dorothy JohnsonSep 9, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • J
    jamesriversSep 12, 2025
    What causes Parker Dehumidifier failure to switch?
    • L
      Lisa TurnerSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

INSPECTION

Verifying dryer condition upon arrival and checking for shipping damage.

Installation

Guidelines for connecting piping, electrical, and ensuring integrity during installation.

Safety and System Precautions

Sequence of Operation

STEP 1- LEFT DRYING; RIGHT REGENERATING

Describes the initial drying and regeneration state of the two towers.

STEP 2 - LEFT DRYING, RIGHT REPRESSURIZING

Details the transition phase where the regenerating tower is repressurized.

STEP 3 - LEFT REGENERATING, RIGHT DRYING

Explains the reversed drying and regeneration state of the two towers.

Sequence of Operation Drawings

Start Up

Shutdown Procedures

Demand Cycles

Maintenance Program

Desiccant Replacement

Spare Parts Lists

Trouble Shooting Guide

Dryer Not Operating (No Lights On)

Troubleshooting steps when the dryer shows no power or activity.

Outlet Dewpoint

Identifying causes and solutions for high dew point readings.

Excessive Air Loss on Regenerating Tower

Diagnosing and resolving air leaks during the regeneration process.

Inlet or Exhaust Valves not functioning

Diagnosing and repairing malfunctioning inlet or exhaust valves.

Wiring Diagrams

High Humidity

Timing Charts

PowerLoc System

Quick-Start for Dryers Equipped with Powerloc

Initial setup and startup steps for dryers with the Powerloc system.

Warranty