HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • R
    reedstephanieAug 19, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • C
      Christine ReedAug 19, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • A
    ashleysimpsonAug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • C
      Charles HarrisAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • H
    Haley KaiserAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • H
      hallannaAug 26, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • D
    Dylan JonesAug 28, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • M
      Marie ColemanAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • A
    aadamsAug 30, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • B
      Brian ChaseAug 30, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • J
    johnwallerSep 2, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • C
      Carol SchaeferSep 2, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • D
    Denise BaileySep 4, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • K
      Karen ThomasSep 4, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • O
    operkinsSep 6, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • J
      Jonathan MurraySep 6, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • V
    Victoria ParsonsSep 9, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • J
      Jordan WilsonSep 9, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • R
    riddlemelissaSep 12, 2025
    What causes Parker Dehumidifier failure to switch?
    • D
      Dr. Sonya WashingtonSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

Inspection and Dryer Location

Guidelines for inspecting the dryer upon arrival and selecting an optimal installation site.

Installation Requirements

Key requirements for proper installation, including piping and pre-filtration.

Safety and System Precautions

General Safety Guidelines

Crucial safety measures including caution, pressure relief, and PPE.

Sequence of Operation

Start Up

Pre-Startup Procedures

Verifying wiring, power, and initial pressurization before system activation.

Shutdown Procedures

Demand Cycles

Powerloc System Overview

Introduction to the Powerloc digital dew point monitor for load-tailored cycles.

Trouble Shooting Guide

Dryer Operation & Switching Issues

Addresses problems like no operation, incorrect switching, and timing faults.

Dewpoint, Moisture, and Air Loss

Solutions for high dewpoint, downstream moisture, and air leaks.

Component Malfunctions and Leaks

Troubleshoots valve leaks, pressure issues, control air, and solenoids.

High Humidity

PowerLoc System

PowerLoc Quick Start and Theory

Initial setup and operational principles of the PowerLoc dew point monitor.

Probe Installation and Connection

Instructions for mounting the sensor probe and connecting it to the analyzer.

Parker Airtek TW 100 Specifications

General IconGeneral
BrandParker
ModelAirtek TW 100
CategoryDehumidifier
LanguageEnglish

Related product manuals