HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • K
    Kelly JonesAug 18, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • S
      Stephanie HillAug 18, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • C
    Carla YatesAug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • S
      Spencer McdowellAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • K
    Kevin SimonAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • C
      christopherwilliamsAug 26, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • S
    Sandra ThomasAug 27, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • O
      Oscar CummingsAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • S
    Savannah WilliamsonAug 29, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • M
      Margaret WrightAug 30, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • B
    Bryan AguirreSep 1, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • D
      Dr. Javier DavisSep 1, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • B
    Brian CamachoSep 3, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • T
      Travis SteinSep 3, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • A
    Ashley WilliamsSep 5, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • G
      garrettjeremySep 5, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • R
    Rebecca StevensSep 8, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • Y
      yvonnewoodardSep 8, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • M
    Mr. Gary StewartSep 10, 2025
    What causes Parker Dehumidifier failure to switch?
    • A
      Amanda FosterSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

Installation

Instructions for making necessary piping and electrical connections for proper dryer installation.

Safety and Operation Principles

Safety and System Precautions

Essential safety measures and precautions to be observed when working with or operating the dryer.

General Operation

Explanation of the adsorption principle and basic operation of desiccant air dryers.

Sequence of Operation

Step 1 - Left Drying; Right Regenerating

Detailed description of the dryer's initial operating state, involving left tower drying and right tower regeneration.

Dryer Start Up and Operation

Start Up Procedure

Step-by-step instructions for safely starting up the AIRTEK dryer, including checks and initial settings.

Demand Cycles and Shutdown

Shutdown Procedures

Procedure for safely isolating the dryer by shutting off power and closing valves.

Maintenance Program

Maintenance Schedule

Routine maintenance tasks categorized by frequency: Daily, Weekly, Semi-Annual, and Annual.

Troubleshooting Guide

Troubleshooting Chart

Guide to identify and resolve common problems encountered with the dryer's operation.

Warranty Information

Warranty Procedure

Steps to follow for warranty claims, including initial contact and information required.

Warranty Parts and Returns

Procedure for ordering warranty parts and managing returns, including RMA process.

Parker Airtek TW 75 Specifications

General IconGeneral
Dehumidification Capacity75 pints per day
Coverage Area4500 sq ft
Operating Temperature41°F - 95°F (5°C - 35°C)
Water Tank Capacity16.9 pints
Noise Level52 dB