HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • H
    Hector LopezAug 18, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • P
      paynesandraAug 19, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • G
    Gabrielle FlemingAug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • S
      smithlauraAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • K
    Kayla AndrewsAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • B
      Brenda TurnerAug 26, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • L
    Lisa BryanAug 28, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • S
      Shirley RiveraAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • J
    Jason TaylorAug 30, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • B
      Brandon MoralesAug 30, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • E
    Erin PhelpsSep 1, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • D
      danielle43Sep 1, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • R
    Robert HuffmanSep 3, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • A
      Alexander MontesSep 3, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • J
    Jennifer RollinsSep 6, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • P
      phillip86Sep 6, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • D
    Denise BurchSep 8, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • M
      Mr. Lance PaulSep 8, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • T
    Timothy WoodardSep 12, 2025
    What causes Parker Dehumidifier failure to switch?
    • C
      Christopher PayneSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

Safety and System Precautions

Safety and System Precautions

Essential safety measures and precautions for operating and servicing the compressed air dryer.

Start Up

Start Up

Step-by-step guide for safely starting the dryer and verifying system parameters.

Maintenance Program

Daily Maintenance

Daily inspection and checks to ensure optimal dryer performance and dew point.

Desiccant Replacement

Procedure and safety precautions for replacing the desiccant material in the dryer.

Inlet and Exhaust Valve Repair

Step-by-step instructions for the repair and maintenance of inlet and exhaust valves.

Trouble Shooting Guide

Dryer Operation Issues

Guidance for diagnosing and resolving issues related to dryer startup, switching, and operation.

Dewpoint and Moisture Issues

Troubleshooting steps for issues concerning dewpoint performance and moisture presence.

Airflow and Pressure Issues

Solutions for airflow restrictions, leaks, pressure drops, and back pressure in the system.

Control Air and Valve Issues

Troubleshooting for control air supply failures, valve malfunctions, and solenoid issues.

Wiring Diagrams

Sequence Annunciator Wiring

Detailed wiring diagram for the sequence annunciator control panel and associated components.

Dew Point Monitor Wiring

Wiring diagram illustrating connections for the dew point monitor and its sensor probe.

High Humidity

Precautions, Limitations, and Hazards

Critical safety warnings, limitations, and hazards associated with the HHA system.

PowerLoc System

Quick-Start for Dryers Equipped with Powerloc

Essential initial setup steps for dryers equipped with the Powerloc dew point monitoring system.

Mounting the Probe

Instructions for the correct installation and mounting of the Powerloc dew point sensor probe.

Warranty

Warranty Procedure

Procedure for initiating a warranty claim and obtaining factory support or service.

Parker Airtek TW 55 Specifications

General IconGeneral
BrandParker
ModelAirtek TW 55
CategoryDehumidifier
LanguageEnglish