HEATLESS DESICCANT
COMPRESSED AIR DRYER
MODEL’S 75 - 6000
S/N
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Service Department
1-800-451-6023

Questions and Answers

  • J
    Jacob MathewsAug 18, 2025
    Why is my Parker Dehumidifier not turning on (no lights)?
    • S
      Stephanie TorresAug 19, 2025
      Your Parker Dehumidifier might not be turning on because of a blown control fuse (replace the fuse), no power supply (apply correct power), or an inoperative solid state controller (replace the controller).
  • V
    Victoria LunaAug 21, 2025
    What to do if Parker Dehumidifier has excessive pressure drop?
    • K
      Karen DavisAug 21, 2025
      If your Parker Dehumidifier has an excessive pressure drop, the pre-filter is likely dirty (replace the element), the afterfilter is dirty (replace the element), or the desiccant is dirty (replace the desiccant).
  • T
    Tracy ClineAug 26, 2025
    What to do if Parker Dehumidifier lights are on, but the dryer doesn't switch?
    • H
      huntloriAug 26, 2025
      If the lights are on but your Parker Dehumidifier isn't switching, it could be due to a control air shutoff (open the valve), the dryer being in PowerLoc, CycleLoc, or ProPurge mode, or the dryer not being in a 100% load cycle (check the setting). For PowerLoc, CycleLoc, or ProPurge modes consult pages 9-10.
  • Q
    qbookerAug 28, 2025
    How to fix excessive air loss on the regenerating tower of Parker Dehumidifier?
    • C
      Cheyenne MorrisAug 28, 2025
      Excessive air loss on the regenerating tower of your Parker Dehumidifier could be due to: * Purge set too high (check specifications and adjust). * Repressurization solenoid leaking (repair or replace). * Inlet valve leaking or not functioning (repair or replace). * Leaking or inoperative control solenoid (repair or replace). * Defective controller (repair or replace).
  • C
    colemanfernandoAug 30, 2025
    Why Parker Dehumidifier unit does not fully repressurize?
    • T
      Taylor HahnAug 30, 2025
      If your Parker Dehumidifier unit does not fully repressurize, it could be due to a purge rate that is too low (adjust purge), leaking exhaust valves (see above), a faulty repressurization solenoid (replace solenoid), or a plugged purge or repressurization orifice.
  • J
    Jeanette MullenSep 1, 2025
    How to eliminate back pressure in regenerating tower in Parker Dehumidifier?
    • G
      gmillerSep 2, 2025
      To eliminate back pressure in the regenerating tower of your Parker Dehumidifier, you should check for clogged mufflers (clean, repair, or replace), leaking check valves (clean, repair, or replace), a purge flow that is too high (adjust), or no output from the controller (replace fuse or controller).
  • A
    Autumn DeanSep 3, 2025
    What causes inlet or exhaust valves not functioning in Parker Dehumidifier?
    • B
      Brian AndersonSep 4, 2025
      Inlet or exhaust valves not functioning on your Parker Dehumidifier can be caused by bad diaphragms or O-rings (rebuild valves available kits or replace), no control air (see below), defective control solenoids (repair or replace), or no output from the controller (repair or replace).
  • R
    rojasthomasSep 6, 2025
    What to do if the exhaust valve on drying or repressurizing tower is leaking in Parker Dehumidifier?
    • S
      smartinSep 6, 2025
      If the exhaust valve on the drying or repressurizing tower of your Parker Dehumidifier is leaking, it could be because the valve is dirty (clean valve), the diaphragms or O-rings are defective (repair or replace), or the control solenoid is leaking (repair or replace).
  • J
    Jacob CabreraSep 8, 2025
    How to troubleshoot no control air at inlet or exhaust valves in Parker Dehumidifier?
    • S
      sharibradySep 8, 2025
      If there's no control air at the inlet or exhaust valves of your Parker Dehumidifier, check if the control air shutoff valve is closed (open it), the control air filter is dirty (replace element), there's a leak in the control air tubing (repair), the control solenoid is defective (repair or replace), or there's no output from the controller (replace fuse or controller).
  • C
    candicebryantSep 12, 2025
    What causes Parker Dehumidifier failure to switch?
    • A
      Andrew SmithSep 12, 2025
      A failure to switch in your Parker Dehumidifier can be caused by a time delay setting that is too short (adjust properly, Failure to Switch option only!). It may also be related to the dryer not operating (see above).

Summary

Installation and Inspection

Safety and System Precautions

Sequence of Operation

Drying Cycle Steps 1-3

Describes the initial phases of the drying cycle, including repressurization.

Drying Cycle Step 4

Start Up

Pre-Start Checks and Initial Pressurization

Essential checks, pressurization, and warnings before operation.

Shutdown Procedures

Maintenance Program

Routine Maintenance Schedule

Comprehensive schedule for daily, weekly, semi-annual, and annual maintenance tasks.

Desiccant Replacement

Trouble Shooting Guide

Dryer Operation and Cycling Issues

Diagnosing and resolving issues with dryer operation and cycling failures.

Dewpoint and Moisture Problems

Troubleshooting high dew point and downstream moisture issues.

Air Leaks and Valve Issues

Repressurization, Back Pressure, and Valve Malfunctions

Control Air and Solenoid Issues

High Humidity

High Humidity Alarm Safety Precautions

Important safety warnings and handling for the HHA.

PowerLoc System

PowerLoc Probe Mounting and Troubleshooting

JC, JT & JL Filters

Troubleshooting Chart

Common Troubleshooting Scenarios

Addresses initial pressure drop, clogging, oil, and filter rupture issues.

Warranty

Warranty Parts and Returns Process

Parker Airtek TW 200 Specifications

General IconGeneral
BrandParker
ModelAirtek TW 200
CategoryDehumidifier
LanguageEnglish

Related product manuals