EasyManuals Logo

Parker DRD Series User Manual

Parker DRD Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
English
5/6
DRD 265-1000
6 Maintenance
a) The machine is designed and built to guarantee continuous opera-
tion; however, the life of its components depends on the maintenance
performed;
b) when requesting assistance or spare parts, identify the machine
(model and serial number) by reading the data plate located on the
unit.
c) An example of this record sheet can be downloaded from the site:
www.polewr.com.
6.1 General instructions
! Before any maintenance, make sure:
the pneumatic circuit is no longer pressurized;
the dryer is disconnected from the main power supply
. Y Always use the Manufacturer’s original spare parts: otherwise the
Manufacturer is relieved of all liability regarding machine malfunctioning
Y In case of refrigerant leakage, contact quali ed and authorized per-
sonnel.
Y The Schrader valve must only be used in case of machine malfunc-
tion: otherwise any damage caused by incorrect refrigerant charging will
not be covered by the warranty.
6.2 Refrigerant.
Charging: any damage caused by incorrect refrigerant replacement car-
ried out by unauthorized personnel will not be covered by the warranty.
Z
Y
At normal temperature and pressure, the R407c refrigerant is a
colourless gas classi ed in SAFETY GROUP A1 - EN378 (group 2  uid
according to Directive PED 2014/68/EU)
GWP (Global Warming Potential) = 1652,5.
! In case of refrigerant leakage, ventilate the room.
6.3 Preventive Maintenance Programme
To guarantee lasting maximum dryer ef ciency and reliability
Maintenance
Activity Description
Maintenance Interval
(standard operating condi-
tions)
Activity
Check
Service
Daily
Weekly
4 Months
12 Months
36 Months
Check POWER ON indicator is lit.
Check control panel indicators.
Check condensate drain.
Clean condenser  ns.
Verify that the crakcase heater is cor-
rectly positioned
Check electrical absorption.
Check refrigerant leaks.
Depressurize the dryer. Complete
drain maintenance.
Depressurize the dryer. Replace pre-
and post- lter elements.
Check temperature sensors.
Replace if necessary.
Dryer maintenance kit.
The following are available (see par. 8.4):
• maintenance kits;
• service kit
individual spare parts.
6.4 Dismantling
The refrigerant and the lubricating oil contained in the circuit must be
recovered in conformity with current local environmental regulations.
%
Recycling Disposal Z
structural work steel/epoxy-polyester resins
exchanger aluminium
pipes/headers copper/aluminium/carbon steel
drain polyamide
exchanger insulation EPS (sintered polystyrene)
pipe insulation synthetic rubber
compressor steel/copper/aluminium/oil
condenser steel/copper/aluminium
refrigerant R407c
valves brass
electrical cables copper/PVC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker DRD Series and is the answer not in the manual?

Parker DRD Series Specifications

General IconGeneral
BrandParker
ModelDRD Series
CategoryDryer
LanguageEnglish

Related product manuals