6 Maintenance
a)  The machine is designed and built to guarantee continuous opera-
tion; however, the life of its components depends on the  maintenance 
performed;
b) when requesting assistance or spare parts, identify the machine 
(model and serial number) by reading the data plate located on the 
unit. 
c)   An example of this record sheet can be downloaded from the site: 
www.polewr.com.
6.1 General instructions
!  Before any maintenance, make sure:
• the pneumatic circuit is no longer pressurized;
• the dryer is disconnected from the main power supply
. Y Always use the Manufacturer’s original spare parts: otherwise the 
Manufacturer is relieved of all liability regarding machine malfunctioning
Y In case of refrigerant leakage, contact quali ed and authorized per-
sonnel.
Y The Schrader valve must only be used in case of machine malfunc-
tion: otherwise any damage caused by incorrect refrigerant charging will 
not be covered by the warranty.
6.2 Refrigerant.
Charging: any damage caused by incorrect refrigerant replacement car-
ried out by unauthorized personnel will not be covered by the warranty. 
Z
Y
  At normal temperature and pressure, the R407c refrigerant is a 
colourless gas classi ed in SAFETY GROUP A1 - EN378 (group 2  uid 
according to Directive PED 2014/68/EU)
GWP (Global Warming Potential) = 1652,5.
! In case of refrigerant leakage, ventilate the room.
6.3  Preventive Maintenance Programme
To guarantee lasting maximum dryer ef ciency and reliability
Maintenance
Activity Description
Maintenance Interval
(standard operating condi-
tions)
Activity
Check 
 Service 
Daily
Weekly
4 Months
12 Months
36 Months
Check POWER ON indicator is lit.
Check control panel indicators.
Check condensate drain.
Clean condenser  ns.
Verify that the crakcase heater is cor-
rectly positioned
Check electrical absorption.
Check refrigerant leaks.
Depressurize the dryer. Complete 
drain maintenance.
Depressurize the dryer. Replace pre- 
and post- lter elements.
Check temperature sensors. 
Replace if necessary.
Dryer maintenance kit.
The following are available (see par. 8.4):
• maintenance kits;
• service kit
• individual spare parts.
6.4 Dismantling
The refrigerant and the lubricating oil contained in the circuit must be 
recovered in conformity with current local environmental regulations.
%
Recycling Disposal Z
structural work steel/epoxy-polyester resins
exchanger aluminium
pipes/headers copper/aluminium/carbon steel
drain polyamide
exchanger insulation EPS (sintered polystyrene)
pipe insulation synthetic rubber
compressor steel/copper/aluminium/oil
condenser steel/copper/aluminium
refrigerant R407c
valves brass
electrical cables copper/PVC