H Series Fieldbus Extension Units, Series A (PSSEXT1 & PSSEXT3) E117P
4
Specifi cations - Following are specifi cations for the H Series Fieldbus extension units.
H Series Fieldbus Extension Units
Operating Temperature IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20 to 60°C (-4 to 140°F)
Storage Temperature IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),
-40 to 85°C (-40 to 185°F)
Relative Humidity IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat):
5 to 95% non-condensing
Shock IEC60068-2-27 (Test Ea, Unpackaged Shock):
Operating 30g
Non-operating 50g
Vibration IEC60068-2-6 (Test Fc, Operating):
5g @ 10 to 500Hz
ESD Immunity IEC 61000-4-2:
6kV contact discharges
8kV air discharges
Radiated RF Immunity IEC 61000-4-3:
10V/m with 1kHz sine-wave 80%AM from 30MHz to 2000MHz
10V/m with 200Hz 50% Pulse 100%AM at 900Mhz
10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz
Emissions CSPR 11:
Group 1, Class A
Enclosure Type Rating Meets IP65/66/67 (when marked)
Mounting Base Screw Torque #8 screw, 7.5 in. lbs. in Aluminum, 16 in. lbs. in Steel
Certifi cations: c-UL-us UL Listed Industrial Control Equipment,
(when product is marked) certifi ed for US and Canada
CE
European Union 89/336/EEC EMC Directive,
compliant with:
EN 61000-6-4; Industrial Emissions
EN 50082-2; Industrial Immunity
EN 61326; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
C- Tick Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
Extension Unit Application Rules
All the following rules apply for both the PSSEXT1 and PSSEXT3
extension unit.
• For all adapters:
Up to four extension units can be used per network adapter.
• The fi rst module after an extension unit must be a PSSSE24A.
A PSSSE24A is needed:
if additional backplane power is needed because of module
current consumption, or
after 2 extension units.
The only exception to this rule is if the modules in the segment
after the extension unit are only PSSTR4M12As. If only this
module is used, NO PSSSE24A is needed. In this case, the Pin
1 on PSSTR4M12A will NOT have 24VDC. Thus load must be
powered by external power. See E109P, Relay Output Module
Instruction Sheet for details.
The number or mix of modules you use between extension cables
does not matter as long as you do not exceed the rated adapter
or PSSSE24A current output.