EasyManua.ls Logo

Parker H Series - PSSNAC Analog Current Input Module; PSST8 Electronically Protected Output Module; PSSTR4 Relay Sink;Source Output Module

Parker H Series
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication PSS-UM001A-EN-P – December 2016
B-2 Default Data Maps
PSST8 Electronically Protected Output Module
Message size: 1 Byte
7 6 5 4 3 2 1 0
Produces (scanner Rx) Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0 Channel Status
Where: Ch0 = output channel 0, Ch1 = output channel 1, Ch2 = output channel 2, Ch3 = output channel 3, Ch4 = output channel 4, Ch5 = output channel 5,
Ch6 = output channel 6, Ch7 = output channel 7; 0 = no error, 1 = error
Message size: 1 Byte
7 6 5 4 3 2 1 0
Consumes (scanner Tx) Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0 Channel State
Where: Ch0 = output channel 0, Ch1 = output channel 1, Ch2 = output channel 2, Ch3 = output channel 3, Ch4 = output channel 4, Ch5 = output channel 5,
Ch6 = output channel 6, Ch7 = output channel 7; 0 = OFF, 1 = ON
PSSNAC Analog Current Input Module
Message size: 6 Bytes
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Produces (scanner Rx) Input Channel 0 High Byte Input Channel 0 Low Byte
Input Channel 1 High Byte Input Channel 1 Low Byte
Status Byte for Channel 1 Status Byte for Channel 0
OR UR HHA LLA HA LA CM CF OR UR HHA LLA HA LA CM CF
Consumes (scanner Tx) No consumed data
Where: CF = Channel Fault status; 0 = no error, 1 = fault
CM = Calibration Mode; 0 = normal, 1 = calibration mode
LA = Low Alarm, 0 = no error, 1 = fault
HA = High Alarm; 0 = no error, 1 = fault
LLA = Low/Low Alarm; 0 = no error, 1 = fault
HHA = High/High Alarm; 0 = no error, 1 = fault
UR = Underrange; 0 = no error, 1 = fault
OR = Overrange; 0 = no error, 1 = fault
PSSTR4 Relay Sink / Source Output Module
Message size: 1 Byte
7 6 5 4 3 2 1 0
Consumes (scanner Tx) Not Used Ch3 Ch2 Ch1 Ch0 Channel State
Where: Ch0 = output channel 0, Ch1 = output channel 1, Ch2 = output channel 2, Ch3 = output channel 3; 0 = OFF, 1 = ON