Introduction
Follow these instructions when installing, operating, or servicing the
product.
H Series Fieldbus 32 Point Valve Driver,
Series A
(PSSV32A)
The sealed IP67 housing of these modules requires no enclosure.
(Note that environmental requirements other than IP67 may require
an additional appropriate housing.) The PSSV32A module is shown
below.
The PSSV32A valve driver module provides an interface between the H
Series Fieldbus serial bus system and the H Series ISO valve assembly.
This module will always be the last module on the H Series Fieldbus
serial bus. It controls 32 digital outputs at 24VDC. Depending on valve
selection, it can control up to 32 single solenoid valves or 16 double
solenoid valves.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning the
product or systems in the current product catalog. Due to the variety of
operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making
the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by Parker Hannifin Corporation and its subsidiaries at any time
without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
Installation & Service Instructions
E100P
H Series Fieldbus 32 Point Valve
Driver, Series A (PSSV32A)
ISSUED: February, 2016
Supersedes: December, 2006
Doc.# E100P, EN# 160064, Rev. C
Pneumatic Division
Richland, Michigan 49083
Mod
PSSV32A
Net
Fault
PSSV32A
Outputs
25- 32
Connector
Outputs
1- 24
Connector
Safety Guide
For more complete information on recommended application guidelines, see
the Safety Guide section of Pneumatic Division catalogs or you can download
the Pneumatic Division Safety Guide at: www.parker.com/safety
WARNING
• To avoid unpredictable system behavior that can cause personal
injury and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnectairsupplyanddepressurizeallairlinesconnectedtothis
product before installation, servicing, or conversion.
• Operatewithinthemanufacturer’sspeciedpressure,temperature,
andotherconditionslistedintheseinstructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Serviceaccordingtoprocedureslistedintheseinstructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• Afterinstallation,servicing,orconversion,airandelectricalsupplies
(whennecessary)should beconnectedand theproduct testedfor
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warningsandspecicationsontheproductshouldnotbecoveredby
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
!