For Size HA & HB Series Valves
For H1, H2, & H3 Series Valves
Item Number Description
1 Gasket
2 Interconnect Jumper Wire
3 Screw
4 Adapter Plate
5 Gasket
6 Adapter - Fieldbus (Turck)
7 Screw
Torque - in. lb. (Nm)
Item 3
25-35 (2.8 - 4.0)
Item 7
8-10 (0.9 - 1.1)
4
G
4
1
14
PRESS
PRESS
G
12
14
G
3/5
3/5
1
1
0
I
X
0
1
1
14
PRESS
PRESS
0
I
X
0
1
1
2
4
3
6
7
5
POWER
1
2
4
3
6
7
5
POWER
Assembly Technique
1. Connect the Wire Harness (Item 2) to the interconnect board
in the valve stack.
2. Fit Gasket (Item 1) into the slot in the Adapter Plate
(Item 4).
3. Pass the Wire Harness through the Adapter Plate.
4. Screw the Adapter Plate to the Valve Stack. Torque the
Screws (Item 3) to specifi cation.
5. Fit Gasket (Item 5) into the Field Bus Adapter (Item 6).
6. Pass the Wire Harness through the Adapter and make the
connection to the Bus Module. Clamp the Bus Module with
the Adapter.
7. Screw the Bus Adapter to the Valve Stack. Torque Screws
(Item 7) to specifi cation.