Introduction
Follow these instructions when installing, operating, or servicing the
product.
H Series Fieldbus 24 VDC Output Modules,
Series A
(PSST8M23A, PSST8M12A, PSST8M8A, PSST16M23A,
PSST16D25A, PSST16M12A)
The sealed IP67 housing of these modules requires no enclosure.
(Note that environmental requirements other than IP67 may require
an additional appropriate housing.) I/O connectors are sealed M8
(pico) or M12 (micro) or M23 or 25-Pin D-Sub styles. The mounting
base ships with the module. The PSST8M23A, PSST8M12A,
PSST8M8A, PSST16M23A, PSST16D25A and PSST16M12A
modules are shown below.
Installation & Service Instructions
E107P
H Series Fieldbus 24 VDC Output
Modules, Series A (PSST8M23A,
PSST8M12A, PSST8M8A, PSST16M23A,
PSST16D25A, PSST16M12A)
ISSUED:
February, 2016
Supersedes: October, 2008
Doc.# E107P, EN# 160064, Rev. D
Pneumatic Division
Richland, Michigan 49083
Female
Connector
M23
PSST8M23A
24V dc Out
PSST8M23A
LED
Indicators
MOD
NET
0
1
2
3
4
5
6
7
8
10 12
9
3
4
6
5
7
11
PSST8M12A
24V dc Out
PSST8M12A
LED
Indicators
Female
Connector
M12-C
Female
Connector
M12-D
Female
Connector
M12-A
Female
Connector
M12-B
MOD
NET
0
1
0
1
2
3
4
5
6
7
2
3
4
5
6
7
PSST8M8A
24V dc Out
PSST8M8A
LED
Indicators
Female
Connector
M8-F
Female
Connector
M8-A
Female
Connector
M8-B
MOD
NET
0
1
0
2
3
4
5
6
7
2
4
6
1
3
5
7
Female
Connector
M8-H
Female
Connector
M8-D
Female
Connector
M8-C
Female
Connector
M8-E
Female
Connector
M8-G
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning the
product or systems in the current product catalog. Due to the variety of
operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making
the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnectelectricalsupply(whennecessary)beforeinstallation,
servicing, or conversion.
• Disconnectairsupplyanddepressurizeallairlinesconnectedto
thisproductbeforeinstallation,servicing,orconversion.
• Operatewithinthemanufacturer’sspeciedpressure,temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Serviceaccordingtoprocedureslistedintheseinstructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies(whennecessary)shouldbeconnectedandtheproduct
testedforproperfunctionandleakage.Ifaudibleleakageispresent,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be
coveredbypaint,etc.Ifmaskingisnotpossible,contactyourlocal
representativeforreplacementlabels.
!
SafetyGuide
For more complete information on recommended application guidelines, see
the Safety Guide section of Pneumatic Division catalogs or you can download
the PneumaticDivisionSafetyGuide at: www.parker.com/safety