Introduction
Follow these instructions when installing, operating, or servicing the
product.
H Series Fieldbus 24 VDC Analog Input
Modules, Series A
(PSSNACM12A, PSSNAVM12A)
The sealed IP67 housing of these modules requires no enclosure.
(Note that environmental requirements other than IP67 may require
an additional appropriate housing.) I/O connectors are sealed M12
style. The mounting base ships with the module. The PSSNACM12A
and PSSNAVM12A modules are shown below.
Installation & Service Instructions
E110P
H Series Fieldbus 24 VDC
Analog Input Modules, Series A
(PSSNACM12A, PSSNAVM12A)
ISSUED: February, 2016
Supersedes: December, 2006
Doc.# E110P, EN# 160064, Rev. C
MOD
NET
PSSNAVM12A
Analog Voltage
In
0
1
0
1
PSSNAVM12A
LED
Indicators
Female
Connector
M12-A
Female
Connector
M12-B
MOD
NET
PSSNACM12A
Analog Current
In
0
1
0
1
PSSNACM12A
LED
Indicators
Female
Connector
M12-A
Female
Connector
M12-B
Pneumatic Division
Richland, Michigan 49083
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning the
product or systems in the current product catalog. Due to the variety of
operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making
the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnectelectricalsupply(whennecessary)beforeinstallation,
servicing, or conversion.
• Disconnectairsupplyanddepressurizeallairlinesconnectedto
thisproductbeforeinstallation,servicing,orconversion.
• Operatewithinthemanufacturer’sspeciedpressure,temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Serviceaccordingtoprocedureslistedintheseinstructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies(whennecessary)shouldbeconnectedandtheproduct
testedforproperfunctionandleakage.Ifaudibleleakageispresent,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be
coveredbypaint,etc.Ifmaskingisnotpossible,contactyourlocal
representativeforreplacementlabels.
SafetyGuide
For more complete information on recommended application guidelines, see
the Safety Guide section of Pneumatic Division catalogs or you can download
the PneumaticDivisionSafetyGuide at: www.parker.com/safety