10
Parker Hannifin Corporation | Pump & Motor Division | Kings Mountain, NC
WARNING: This product can expose you to chemicals including lead or DEHP which are known to the state of California to cause cancer,
birth defects, and other reproductive harm. www.p65warnings.ca.gov
Disassembly InstructionsDisassembly Instructions
12) Remove thrust plate and examine for wear.
Wear on thrust plate will reveal exactly what
happened to the thrust plate (Fig. 12).
Examples of damaged plates (Fig. 12a & 12b).
Figure 12
Figure 12a
Figure 12b
13) Examine top of Shaft End Cover as well as bushings
and lip seal for wear or damage. Ensure that they
are free of debris (Fig. 13).
Figure 13