8
PSE 120-350
9.3 TECHNICAL DATA
Model
Weight
Refrigerant
R513A
of
coolers
MIN.- MAX
Ambient Temperature
Amb
Compressed
air inlet
Temperature
In
F.L.A.[A]
400V±10%/3Ph/50Hz
460V±10%/3Ph/60Hz
MOP MCA
IP
Minimum
section
validated
cable for
electrical
connection
Sound
pressure
level
During
transport
and
stockage
After
installation
Ac Wc
Kg Kg CO
2
e
(t) Kg
CO
2
e
(t)
°C °C °C A A A - Ø [mm2] [dB (A)]
PSE 120
205 1.6 0.92 - -
1 0-50 5-50 5-65
6.54 10 8.5
44
4G2.5
<75
PSE 140
205 1.6 0.92 - -
PSE 180
210 1.3 0.75 - - 6.8 10 8.5
PSE 220
260 2.0 1.15 3.0 1.72 9.3 15 11.5
54
PSE 260
262 2.0 1.15 2.8 1.61
10.6
20 13
PSE 300
264 2.0 1.15 3.0 1.72 20 13
PSE 350
270 2.0 1.15 3.1 1.78 13.8 25 17 4G4
Calibration values
Hot gas
valve
12 - HGV
Pressure
condensation
High
pressure
Switch
13-HP
Low
pressure
Switch
9-LP
Operating
Pressure
Water
pressostatic
valve
3-WPV
Compressed
air
inlet/outlet
Water
condensation
inlet/outlet
Condensate
drain
PSE 120/180
2.4-2.6 bar
8 bar - OFF
11 bar - ON
20 bar 1.0-2.0 bar 14 bar
- 2" BSPP-F -
1/2" BSP-F
PSE 220/260
10-11 bar 2".1/2 BSPP-F
1/2" BSPP-F
PSE 300/350
3/4" BSPP-F

Table of Contents