Bulletin MSG30-3254-INST/UK
Installation and setup
manual
Electro-hydraulic control
for serie PVplus
Pump design series 44-45-46-47,
compensator design series 45
Eective: July 1st, 2021
Supersedes: March 1st, 2017
Visit our homepage
for additional support
parker.com/pmde

Other manuals for Parker PV028

Questions and Answers

  • J
    jesse61Sep 13, 2025
    What to do if Parker PV028 Water Pump drive motor only turns at slow speed?
    • R
      Rebecca SmithSep 13, 2025
      If the drive motor of your Parker Water Pump only turns at slow speed, consider the following: * **Motor selection:** Use a motor with more horsepower if the current motor is not selected properly. * **Hydraulic blockage:** Check the function of the pump compensator and start the pump at an unloaded system if the pump is hydraulically blocked.
  • T
    tamaralindseySep 15, 2025
    What to do if Parker Water Pump does not upstroke, sticks at zero displacement?
    • B
      bakerjasonSep 15, 2025
      If your Parker Water Pump does not upstroke and sticks at zero displacement, consider these potential causes: * **Contamination:** The compensator may be blocked due to contamination. Clean the hydraulic fluid and the compensator valve. * **Wiring issue:** The cable to the LVDT or proportional solenoid may be interrupted. Check the wiring and replace the cable if necessary.
  • E
    Emily TrujilloSep 17, 2025
    What to do if Parker PV028 Water Pump drive motor turns, but the pump does not turn?
    • T
      timothysimsSep 17, 2025
      If the drive motor of your Parker Water Pump turns, but the pump itself does not, check the coupling assembly and correct it, as it might not be mounted correctly.
  • J
    John MillerNov 19, 2025
    What to do if Parker PV028 Water Pump delivers full flow at low pressure?
    • J
      John BooneNov 19, 2025
      If your Parker Water Pump delivers full flow at low pressure, several issues could be the cause. The standard pressure compensator might be set to minimum pressure, so you should adjust the compensator setting to the desired pressure. Alternatively, the orifice in the remote pressure compensator could be blocked, so ensure the orifice Ø 0.8 mm in the control spool is free and open. Other potential causes include: a missing pressure pilot valve connected to port P. R (install a suitable pressure pilot valve and adjust it); an unenergized multiple pressure pilot selector valve (energize the selector valve solenoid); a missing load sensing line (connect the system load sensing port to the compensator); a closed or too small load sensing valve (open the load sensing valve or use a larger valve...

Summary

Table of available electro hydraulical controls

Proportional displacement control, code FDV (old: FPV)

Proportional displacement control with pressure compensation, codes UDR, UDK (old: UPR, UPK)

Function description UDR; UDK (old: UPR; UPK)

The position of the control spool of the pressure compensator is controlled by the pressure drop across the pilot orifice Bp and by the compensator spring.

Proportional displacement control with closed loop pressure control, code UDM (old: UPM)

Preload valve for proportional controlled pumps, code PVAPVV

External pilot pressure supply

Quick pressure relief with quick unload valve, code R5 V in combination with controls codes UDS resp. UDQ

Preload and quick unload manifold PVAPVE in combination with compensator codes UDP resp. UDF

Basic adjustment

Basic adjustment of CIP sensor

The contactless inductive position transducer for displacement feedback (CIP) and compensator valves are factory preset and secured.

Basic adjustment LVDT

The inductive position transducer for displacement feedback (LVDT) and compensator valves are factory preset and secured.

Basic adjustment control valves

Adjustment of remote pressure compensation stages for p-Q controls like UDR, UDK, UDM, UDS, UDP, and UDF.

Connecting diagram for proportional displacement control; Code FDV.

Connecting diagram for p;Q-control; Codes UDR, UDK, UDM, UDS, UDQ, UDP and UDF.

Cables and connections

Cable 1 from CIP and LVDT (displacement transducer)

Details on connecting the CIP and LVDT displacement transducer to the PQ-module and cable specifications.

Cable 2 from pressure sensor (compensator codes UPM, UPF, UPQ)

Details on connecting the pressure sensor to the PQ-module and cable specifications.

Cable 3 a;b to displacement control valve (displacement control)

Specifies connections for solenoid A and B to the displacement control valve and cable details.

Cable 4 to proportional pressure pilot valve solenoid (not for FDV, UDR, UDP, UDS)

Details connections for the proportional pressure pilot valve solenoid and cable specifications.

Trouble shooting guide

Parker PV028 Specifications

General IconGeneral
Displacement28 cc/rev
MountingSAE A 2-Bolt
Speed (Maximum)3000 RPM
Flow Rate84 l/min
RotationClockwise/Counter-clockwise

Related product manuals