- 15 - PATON ECO DC MMA
Beginning on page 52
Fault Reason Solution
Arc extinction occurs
sporadically during
welding
The arc voltage of the
electrode used is too high
If possible, use other electrodes or a
welding unit of higher power
MMA electrode sticks
to the workpiece
Welding current too low
Set a higher welding current
Poor weld quality
(heavy spatter)
Wrong electrode polarity
Reverse the polarity of the electrode
(according to the electrode
manufacturer)
Poor ground contact
Fix the ground terminal as close as
possible to the welding area
11. SAFETY RULES
GENERAL
The welding unit is manufactured in accordance with technical standards and
established safety rules. However, if handled incorrectly, there is a hazard of:
- injury to service personnel or a third party;
- damage to the unit itself or to the company’s material assets;
- disruptions to an effective workflow.
All persons involved in the commissioning, operation, care and maintenance of the
unit must
- be appropriately certified;
- have expertise in welding;
- strictly follow these instructions.
The malfunctions that could impair safety must be urgently rectified.
USER RESPONSIBILITIES
For personal protection, observe the following rules:
- wear protective footwear that retains insulating properties, even in wet conditions;
- protect hands with insulating gloves;
- protect eyes with a protective mask with an anti-UV filter that meets safety
standards;
- use only suitable (highly inflammable) clothing.
PERSONAL PROTECTIVE EQUIPMENT
For personal protection, observe the following rules:
- wear protective footwear that retains insulating properties, even in wet conditions;
- protect hands with insulating gloves;