HIGH-5
INSTALLATION INSTRUCTIONS
For an electronic copy of these instructions, please visit www.pattersonfan.com/installation-services-and-guides
208-230/460V Three-Phase Input using ABB ACS355 VFD

Other manuals for Patterson HIGH-5

Question and Answer IconNeed help?

Do you have a question about the Patterson HIGH-5 and is the answer not in the manual?

Patterson HIGH-5 Specifications

General IconGeneral
ModelHIGH-5
ManufacturerPatterson
CategoryFan
SpeedVariable
Diameter8-24 ft
TypeHigh Volume Low Speed (HVLS)

Summary

Safety Information

General Safety Warnings

Covers installation, servicing, maintenance, and component compatibility warnings.

Included Components

Mechanical Items Included

Lists mechanical parts provided for fan installation.

Electrical Items Included

Lists electrical components provided for fan installation.

Fan Safety Components

Lists safety components included with the fan.

Installation Tools

Tools for Installation

Lists necessary tools for starting fan installation.

Fan Placement and Clearance

Placement, Spacing, and Clearance

Details minimum mounting height and blade clearance requirements.

Maintenance Procedures

VFD Box, Gearbox, and Hub Maintenance

Covers maintenance for VFD box, gearbox oil, and hub grease.

Mounting Hardware and Blade Maintenance

Covers checking mounting hardware tightness and cleaning fan blades.

Mechanical Installation

Mount to Existing I-Beam

Instructions for mounting the fan bracket to an I-beam structure.

Mount Between Bar Joists

Instructions for mounting the fan bracket to bar joists.

Attach Fan Assembly to Bracket

Securing the fan assembly to the installed mounting bracket.

Attach VFD to Fan

Mounting the Variable Frequency Drive (VFD) to the fan frame.

Install Safety Cable

Instructions for installing the required safety cable for the fan.

Install Guy Wires

Procedures for installing guy wires for fan stability.

Install Fan Blades & Safety Bracket

Attaching fan blades and securing the blade safety bracket.

Prepare Gearbox Vent

Final step to remove gearbox plug and install vent cap.

Electrical Installation

Breaker Sizing

Recommends circuit breaker sizing based on voltage and motor horsepower.

Input Power Cable and Disconnect

Connecting input power cable and installing the lockable disconnect.

Motor Cable Connection

Connecting both ends of the motor control cable to the VFD and fan motor.

Remote Keypad and VFD Connection

Mounting the remote keypad and connecting it to the VFD.

VFD to Fire Suppression System

Optional connection of the VFD to a fire suppression system.

Daisy Chaining

Wiring and VFD Configuration

Explains master/follower setup and wiring for daisy chaining VFDs.

Speed Scaling Procedure

Steps to scale follower fan speeds to match the master fan.