Page 63
PRINTER PROTOCOL
Data transmission protocol to Plus Printer
Printing can be started by pressing a key (see section FUNCTION OPERATIONAL) or by input (see
paragraph SETTING I/O).
Here is an example of printer.
216/06/16 15:32
Net 209.0 kg
Gross 211.5 kg
Tare 2.5 kg
Peak 268.5 kg
Code 212456
• Date is printed only in case of hardware with time clock.
• The peak value is only printed if the peak function is enabled.
• The identification code of the weighing is printed only in case of METRIC operation and
alibi memory configured.
The conditions to printing are:
• Stable weight (or stabilized within 3 seconds from command).
• Since the last executed weigh, the weight has undergone a change of at least 20 divisions (delta
weight).
• Gross weight equal to or greater than the minimum weight (20 divisions) and less than the maxi-
mum capacity.
• Net weight not null.
Only in case of FREE functioning, printing is permitted even with gross weight less than the minimum
weight or with zero net weight.