OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Hearth & Home High Burn End Time: 60 PM Control Modules: 335,336
PP130B Medium Burn End Time: 180 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
14.69 ft/sec.
2266 360 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 162.3 scfm
0135PS041E
5 min Dilution Tunnel H2O: 2.00 percent
167.4 scfm
Dilution Tunnel Static: -0.200 "H2O Post-Test Leak Check (1): 0.000 cfm @ 5 in. Hg
11:57 Background Sample Volume: 54.966 cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 5 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 5.91 Dry Basis %
Meter Box Y Factor: 0.977 (1) 0.979 (2) 1 (Amb)
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
30.40 30.44 30.42 "Hg
Initial dP 0.048 0.052 0.052 0.038 0.036 0.050 0.054 0.046 0.060
"H2O
OMNI Equipment Numbers:
Temp: 97 97 98 98 98 98 98 98 98
°F
V
strav
14.83
ft/sec
V
scent
16.56
ft/sec
F
p
0.896
Particulate Sampling Data
Dilution
Tunnel
Center
dP
Stack Filter 1 Filter 2 Ambient
350 57.630 55.832 0.17 0.16 1.36 81 2.01 1.09 81 1.3 74 0.062 98 98 6.1 -0.2 148 70 70 69 -0.026 4.5 0.01022
355 58.456 56.630 0.17 0.16 1.35 81 2.01 1.09 81 1.3 73 0.063 97 97 6.0 -0.1 145 70 69 69 -0.026 2.48 0.0626
360 59.281 57.428 0.16 0.16 1.35 81 2.01 1.08 81 1.2 73 0.062 98 98 5.9 -0.1 146 69 69 69 -0.026 2.42 0.07169
Avg/Tot 59.281 57.428 0.16 0.16 1.33 81 1.99 1.08 82 1.18 84 0.06 100 100 197 72 72 71 -0.034 4.50 0.03
Control No. P-SFDK-0003, Effective Date 5/6/16 File - 135PS041E PP130 Run 1, Tab - Data Entry