4
Acid Soaking the Filter Cartridges
After an extended period of operation, it may be necessary to soak the cartridges in an acid solution. Acid soaking will
remove algae, calcium carbonate, iron and other mineral build-ups from the cartridges. If not removed, these mineral
deposits can lead to the restriction of water ow through the lter and can impede e󰀩cient operation of the equipment.
Muriatic acid is corrosive and can lead to inammation or burns to body tissue.
ALWAYS wear rubber gloves, safety glasses and an N-95 dust mask when handling acid to prevent serious bodily injury.
To prevent degradation of the acid by UV light, store muriatic acid in an opaque container and away from direct sunlight.
RECOMMENDED EQUIPMENT:
Large Plastic Container
Garden Hose with a Straight Flow Nozzle
Muriatic Acid (stored in opaque container)
Rubber Gloves
Safety Glasses
N-95 Dust Mask
PROCEDURE:
1. Remove all oils and cleaning solutions from the cartridges.
Acid soaking without performing this step will result in permanent restriction of water ow through the lter and
premature cartridge failure.
2. Put on protective equipment - rubber gloves, safety glasses and
N-95 dust mask.
3. In a large plastic container, create a solution of one part muriatic
acid to twenty parts water. See FIGURE 5.
Always introduce the muriatic acid as close to the water's
surface as possible. This will minimize splash and reduce
the risk of user contact with the acid.
4. Gently place the bottom of the cartridges into the acid solution.
Allow the cartridges to soak in the solution for 10 minutes, or
until bubbling stops.
5. Turn the cartridges over, placing the top halves into the solution.
Allow the top halves of the cartridges to soak for 10 minutes, or
until bubbling stops.
6. Remove the cartridges from the acid solution.
7. Using a garden hose with a straight ow nozzle, thoroughly
wash down the entire lter element. Wash from the top down,
holding the nozzle at a 45-degree angle to the cartridge. See
FIGURE 4, page 4.
8. Reinstall the cartridges and dispose of the acid solution in
accordance with local regulations.
9. Follow Reinstalling the Filter Lid and Clamp Ring on page 5 exactly.
MURIATIC
ACID
WATER
FIGURE 5

Other manuals for Pentair CLEAN AND CLEAR PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair CLEAN AND CLEAR PLUS and is the answer not in the manual?

Pentair CLEAN AND CLEAR PLUS Specifications

General IconGeneral
Filter TypeCartridge
Flow Rate150 GPM
Cartridge Quantity4
Max Pressure50 psi
MaterialFiberglass-reinforced composite
Inlet/Outlet Size2 inches
Cartridge MaterialPolyester
Filter AreaVaries by model (see product documentation)
DimensionsVaries by model (see product documentation)
WeightVaries by model (see product documentation)

Related product manuals