2 EVERPURE
®
EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
INTRODUCTION
This Everpure EverDri High Capacity Compressed Air System
by Pentair is intended to be the primary driver for actuating
the following types of equipment in a restaurant, which are
currently being driven by CO
2
:
• Bag-in-Box (BIB) Syrup Pumps for Soft Drinks
• Mechanics of the Automated Beverage System (ABS)
• Product Pumps in the Blended Ice Machine (BIM)
• Bulk Ketchup Pumps
• Next Generation Iced Tea Brewers
• Any additional equipment powered by CO
2
The EverDri High Capacity Compressed Air System is
designed to output a constant air pressure for operating
restaurant equipment. During normal operation, the
compressor will automatically cycle on and off as
compressed air is needed. The compressor automatically
turns on at the "cut-in" pressure, typically near 95 psig (6.5
bar). When the air pressure in the compressor tank reaches
~ 125 psig (8.6 bar), the compressor has reached "cut-out"
pressure and will automatically turn off. Elevated noise levels
are normal when the compressor switches off as pressure is
relieved within the enclosure. The compressor system also
has a cooling fan mounted to the enclosure that is designed
to run continuously.
INSPECTION
Inspect the box and skid for damage or tampering due
to transportation. If damaged, immediately contact the
transportation company.
NOTE: Do not cut the tape on the top of the box. This may
damage the Compressor cabinet.
Cut and remove two band straps. Lift cardboard box straight
up and remove protective cardboard on top and plastic bag.
Check for any loose nuts or bolts inside the cabinet and on
the legs. Tighten if necessary. Certify that all damaged parts
are replaced and that all mechanical and electrical problems
are solved before operating the equipment.
Before installing the Everpure EverDri Compressed Air
System, inspect the parts. Use the table and illustration
provided to verify the parts and quantities provided. If any
parts are missing, contact Customer Service at 800.942.1153
(US only)/630.307.3000 or by email at cseverpure@pentair.
com.
Installation
and
Operation
Guide
1
2
Parts Qty
1. Cabinet with Compressor System 1
2. Installation and Operation Guide 1
Tools and Supplies Required
• Safety Glasses
• Cut-Resistant Gloves
• Hearing Protection
• Pliers
• Carpenters Level
• Large Flat Blade Screwdriver
• Wrench (for tubing connection)
• Utility Knife or Tube Cutter (for plastic tubing)
• Oetiker Clamps
• Barbed Tubing Connectors
• Plumber's Tape
• Approved Tubing
• Compressed Air Tubing rated to 150 psig (10.3 bar)
NOTE: Not all tools listed may be necessary for installation.
Read installation procedures before starting to
determine required tools.
WARNING: Before installing the system, make certain
your installation complies with the following
operating specifications. Failure to do so may
reduce the effectiveness of the system and will
void the warranty.
GENERAL PRECAUTIONS
WARNING: To avoid unpredictable system behavior that can
cause personal injury and property damage:
• Disconnect electrical supply before
installation or servicing.
• Release all pressure in the tank before
performing any maintenance.
• Disconnect air supply and depressurize all
air lines connected to this product before
installation or servicing.