4 EVERPURE
®
EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
WARNING: To reduce the probability of an accident because
of contact with rotating parts:
• Do not operate the product, under any
circumstances, when the safety guards of the
rotating parts are not installed.
• Do not wear long clothing, chains or jewelry
that may come into contact with the moving
parts of the product during service. If you have
long hair, tie it back.
• Remove all adjustment tools before turning
your equipment on. A key or tool stuck in
rotating parts of the equipment may cause
serious injuries.
NOTE: The user of this product must maintain the air tank's
record book provided by the manufacturer until the
equipment is no longer in service. The end user
must follow the standards required locally regarding
installation, maintenance, and operation of the
compressed air tank.
NOTE: The hydrostatic test carried out during the product
manufacturing does not replace the initial inspection,
which must be carried out at the location where the
product is installed, duly monitored by a certified
professional, following local codes.
NOTE: All local codes and safety procedures must be
followed.
SELECTING A LOCATION
1. Give consideration to the weight of the unit when
operating. Operating weight of the Everpure EverDri
Compressed Air System is approximately:
• 195 lbs (88.5 kgs)
2. The location should allow for:
• Six (6) inches of clearance on all sides for connections
and air flow.
• Adequate space for the outlet air line connection on
the right side.
• Be near a drain for removing coalesced water.
• Use of the eight (8) foot power cord using standard
grounded wall plug rated for 15 amps minimum.
3. Do not install the Everpure EverDri Compressed Air
System in an area with a high amount of dust, particulates
or moisture. If this is unavoidable, review the maintenance
cycles and decrease the time between filter changes.
4. The floor should be flat and level.
5. Install indoors.
DIMENSIONS
Clearance
Required
Clearance
Required
24"
(60 cm)
36"
(91 cm)
24"
(60 cm)
20.9"
(53 cm)
6"
(15 cm)
Figure 1
SPECIFICATIONS
Weight: Approximately 195 lbs (88.5 kg)
Electrical Connection: 115 VAC, single phase, 60 Hz; GFCI
or RCD protected 15 amp circuit
Operating Environment
Temperature:
41 - 105°F (5 - 40.5°C) continuous
Tank Capacity: 8 gallons (30 L)
Maximum
Tank Pressure
Requirements:
150 psig (10.3 bar) maximum
Outlet Air Pressure: 90 - 95 psig (6.2 - 6.5 bar)
regulated
Outlet Shut-off Valve: 1/4" FNPT
Pressure Relief Valves: Rated to 150 psig (10.3 bar)
Air Quality Output: ISO 8573-1 Class 1 for particulates
ISO 8573-1 Class 3 for moisture
content
ISO 8573-1 Class 0 for oil content,
oil free