7 EVERPURE
®
EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Application
Air Compressor
Inlet
Backup CO
2
Inlet
Normal Operation
Figure 4
2. Unplug the power cord.
3. CLOSE the compressed air outlet valve (Figure 5) so the
blade is perpendicular to the valve body. OPEN cabinet
door. Use a large flat blade screwdriver to unscrew the
two (2) door lock screws.
Open
Closed
Figure 5
4. Replace the fan prefilter.
• OPEN the left side cabinet vent cover by pulling out on
the top edge, Figure 6. The cover will swing down.
• Remove the air prefilter and discard.
• Place the new prefilter into the opening. The soft side
of the filter should be facing out, away from
the cabinet.
• CLOSE the vent cover. It will snap closed.
Pull out on
top edge
Figure 6
5. Replace the two (2) compressor intake filters.
• Unscrew the filters on the left side by hand, (Figure 7)
(counterclockwise). A wrench may be used if needed.
• Discard the old filters.
• Remove any loose plumber's tape from fittings.
• The new filters have "IN" and "OUT" moulded into the
ends. The fitting on the end marked "OUT" screws into
the compressor head. Firmly hand tighten each one by
turning clockwise. Do not tighten with wrench.
Remove
IN
Compressor
Air Intake (2)
OutIn
Air Tank Valve
Figure 7
6. Check for water in air tank.
• OPEN the valve located at the bottom of the air tank.
The compressed air will escape through the valve.
• Observe the air. It must not contain any moisture.
• CLOSE the valve located at the bottom of the air tank
after all air has been vented.
CAUTION: If moisture is present, refer to the
Troubleshooting section in this manual. Do not
vent air toward any body part.
7. Close and lock the cabinet door.
NOTE: Have a stopwatch ready to record the compressor
runtime.
8. Restart the EverDri Compressed Air System.
NOTE: Measure and record the date, the hour meter time
(upper left side) and the time it takes to pump up the
system. If the pump up time is greater than two (2)
minutes, 50 seconds, see Troubleshooting.