FLECK 2850 Control Valve Service Manual 7
approximately three hours and stop in the position shown in
the drawing.
4. Even though it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit
might be set for only one half of this time.
5. In any event, conditioned water may be drawn after rinse

Immediate Regeneration Timers
These timers do not have a 24 hour gear. Setting the gallons
on the program wheel and manual regeneration procedure are
the same as previous instructions. The timer will regenerate as
soon as the capacity gallons reaches zero.
NOTE: Theprogramwheeltotheleftmaybedifferentthan
theprogramwheelontheproduct.
NOTE: Tosetmetercapacityrotatemanualknobone-360°
revolutiontosetgallonage.
61502-3200 Rev A
Figure 3
3200,3210,3220,3230REGENERATION
CYCLESETTINGPROCEDURE
How To Set The Regeneration Cycle Program
The regeneration cycle program on your water conditioner has
been factory preset, however, portions of the cycle or program
may be lengthened or shortened in time to suit
local conditions.
3200 Series Timers (Figure 4)
1. To expose cycle program wheel, grasp timer in upper left-
hand corner and pull, releasing snap retainer and swinging
timer to the right.
2. To change the regeneration cycle program, the program
wheel must be removed. Grasp program wheel and squeeze
protruding lugs toward center, lift program wheel off timer.
Switch arms may require movement to
facilitate removal.
3. Return timer to closed position engaging snap retainer in
back plate. Make certain all electrical wires locate above
snap retainer post.
TimerSettingProcedure
How To Change The Length Of The Backwash Time
The program wheel as shown in the drawing is in the service
position. As you look at the numbered side of the program wheel,
the group of pins starting at zero determines the length of time
your unit will backwash.
For example, if there are six pins in this section, the time of
backwash will be 12 min. (2 min. per pin). To change the length of
backwash time, add or remove pins as required. The number of
pins times two equals the backwash time in minutes.
How To Change The Length Of Brine And Rinse Time
1. The group of holes between the last pin in the backwash
section and the second group of pins determines the length of
time that your unit will brine and rinse (2 min. per hole).
2. To change the length of brine and rinse time, move the rapid
rinse group of pins to give more or fewer holes in the brine and
rinse section. Number of holes times two equals brine and
rinse time in minutes.
How To Change The Length Of Rapid Rinse
1. The second group of pins on the program wheel determines
the length of time that your water conditioner will rapid rinse
(2 min. per pin).
2. To change the length of rapid rinse time, add or remove pins
at the higher numbered end of this section as required. The
number of pins times two equals the rapid rinse time
in minutes.
How To Change The Length Of Brine Tank Rell Time
1. The second group of holes in the program wheel determines

brine tank (2 min. per hole).
2. 
end of the second group of holes as required.
3. The regeneration cycle is complete when the outer
microswitch is tripped by the two pin set at end of the brine

4. The program wheel, however, will continue to rotate until the
inner micro switch drops into the notch on the
program wheel.
Figure 4
61502-3210 Rev A