2FLECK 2900S Service Manual
TABLE OF CONTENTS
JOB SPECIFICATION SHEET 2
INSTALLATION 3
START-UP INSTRUCTIONS 3
3200 TIMER SETTING PROCEDURE 4
3210 & 3220 TIMER SETTING PROCEDURE 4
3200, 3210, 3220, 3230 REGENERATION CYCLE SETTING
PROCEDURE 5
3200 TIME CLOCK TIMER ASSEMBLY 6
3210 METER DELAYED TIMER ASSEMBLY 8
3220 METER IMMEDIATE TIMER ASSEMBLY 10
3230 REMOTE START TIMER ASSEMBLY 12
UPPER ENVIRONMENTAL POWERHEAD ASSEMBLY 14
LOWER ENVIRONMENTAL POWERHEAD ASSEMBLY 16
CONTROL VALVE ASSEMBLY 18
CONTROL VALVE SIDE MOUNT ADAPTER 21
1600 SERIES BRINE SYSTEM 22
1650 BRINE SYSTEM ASSEMBLY 24
1700 BRINE SYSTEM ASSEMBLY 26
1710 BRINE SYSTEM ASSEMBLY 28
2” BRASS METER ASSEMBLY 29
2” PLASTIC METER ASSEMBLY 30
1600 SERVICE VALVE OPERATOR (NEW STYLE) 31
2300 SAFETY BRINE VALVE 32
2310 SAFETY BRINE VALVE 33
2350 SAFETY BRINE VALVE 34
GENERAL SERVICE HINTS FOR METER CONTROL 35
TROUBLESHOOTING 36
WATER CONDITIONER FLOW DIAGRAMS - DOWNFLOW 37
WATER CONDITIONER FLOW DIAGRAMS - UPFLOW 38
FLOW DATA & INJECTOR DRAW RATES - DOWNFLOW 39
ENVIRONMENTAL BACKPLATE DIMENSIONS 40
SYSTEM #4 41
SYSTEM #5 INTERLOCK 41
SYSTEM #6 & #7 42
SYSTEM #4 WIRING 43
SYSTEM #5 WIRING 45
SYSTEM #6 WIRING 46
SYSTEM #7 WIRING 47
1600/1700 SYSTEM NOZZLE & THROAT CHART 49
SERVICE ASSEMBLIES 50
JOB SPECIFICATION SHEET
Job Number: ______________________________________________
Model Number: ____________________________________________
Water Hardness: __________________________________ppm or gpg
Capacity Per Unit: __________________________________________
Mineral Tank Size: ___________ Diameter: ________Height: ________
Salt Setting per Regeneration: _______________________________
1. Type of Timer:
A. 7 Day or 12 Day
B. Meter Initiated
2. Downflow: Upflow Upflow Variable
3. Meter Size:
A. 3/4-inch Std Range (125 - 2,100 gallon setting)
B. 3/4-inch Ext Range (625 - 10,625 gallon setting)
C. 1-inch Std Range (310 - 5,270 gallon setting)
D. 1-inch Ext Range (1,150 - 26,350 gallon setting)
E. 1-1/2 inch Std Range (625 - 10,625 gallon setting)
F. 1-1/2 inch Ext Range (3,125 - 53,125 gallon setting)
G. 2-inch Std Range (1,250 - 21,250 gallon setting)
H. 2-inch Ext Range (6,250 - 106,250 gallon setting)
I. 3-inch Std Range (3,750 - 63,750 gallon setting)
J. 3-inch Ext Range (18,750 - 318,750 gallon setting)
K. Electronic ____Pulse Count ___ Meter Size ____________
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regenera-
tion
B. System #4: Time Clock
C. System #4: Twin Tank
D. System #5: 2-5 Tanks, Interlock Mechanical
2-4 Tanks, Interlock Electronic
Meter per unit for Mechanical and Electronic
E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration, Mechanical
2-4 Tanks, 1 Meter, Series Regeneration, Electronic
F. System #7: 2-5 Tanks, 1 Meter, Alternating
Regeneration,Mechanical
2 Tanks only, 1 Meter, Alternating
Regeneration, Electronic
G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating
H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve.
Brings units on and offline based on flow.
5. Timer Program Settings:
A. Backwash: ______________________________ Minutes
B. Brine and Slow Rinse:_____________________ Minutes
C. Rapid Rinse: ____________________________ Minutes
D. Brine Tank Refill: ________________________ Minutes
E. Pause Time: ____________________________ Minutes
F. Second Backwash: _______________________ Minutes
6. Drain Line Flow Control: gpm
7. Brine Line Flow Controller: gpm
8. Injector Size#:
9. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass