Non-Factory Settings
After all parameters in Master Programming have been set,
these settings can be saved to a custom profile by pressing
on the main Master Settings screen (see Figure 17 Master
Settings Screen). After pressing , the Non-Factory Settings
screen appears.
Figure 27 Non-Factory Settings Screen
Press to save all programmed Master Settings parameters
to non-factory settings. At any point, the control can be reset
to these saved custom settings (see "MASTER RESET" on
page 16). By performing a custom reset, any setting that
is subsequently programmed without saving to non-factory
settings will be reset to the previously saved non-factory
settings in the control.
Diagnostics
The control records and displays a variety of diagnostic data to
assist with troubleshooting performance issues and fine-tuning
system efficiency. Press the Diagnostics button from the
Master Settings or Home screens to view the Diagnostic
screen.
Figure 28 Diagnostic Screen
MASTER SETTINGS PROGRAMMING
continued
• Press the screen navigation arrows at the upper-right and
left of the screen to view each diagnostic parameter.
• Press the Home button to return to the Home screen.
NOTE: If a regeneration occurs while in the Diagnostic screen,
the unit will return to the main screen.
Parameter Description
Flow Rate Displays the current flow rate.
Peak Flow Displays maximum flow rate of water along
with date and time of occurrence, since last
reset.
Totalizer Displays total volume of water used since
last reset.
Last Regen Displays when last regeneration occurred.
Reserve Displays the reserve volume based on the
reserve type selected under master settings.
*This parameter is only available for meter
delayed regeneration type.
Software Ver Displays the software version installed on
the controller.
No of Regens Displays how many manually and system
initiated regenerations the system has gone
through since last reset.
Regen Interval Displays the average length of time between
regenerations based on the past four
regenerations.
Daily Usage Displays average water usage for each day of
the week based on the usage on that day for
the past six weeks.
Usage Since Regen Displays water usage since last regeneration.
Last Setting Change Displays the date and time of the last update
to Master Settings.
NOTE: Only Peak Flow and Totalizer can be changed - they
can be reset to zero.
NOTE: Totalizer has a maximum value of 99,999,999. If this
number is reached, the Totalizer must be reset to zero
to continue tracking this value.
14 • FLECK 5810 & 5812 XTR2 Service Manual