12FLECK Model ProFloSXT Downflow Service Manual
DIAGNOSTIC PROGRAMMING MODE
Diagnostic Programming Mode Options
Abbreviation Parameter Description
FR Flow Rate Displays the current outlet
flow rate
PF Peak Flow Rate Displays the highest flow rate
measured since the
last regeneration
HR Hours in Service Displays the total hours that the
unit has been in service
VU Volume Used Displays the total volume of
water treated by the unit
RC Reserve Capacity Displays the system’s reserve
capacity calculated from the
system capacity, feedwater
hardness, and safety factor
SV Software Version Displays the software version
installed on the controller
NOTE: Some items may not be shown depending on
timer configuration.
The timer will exit Diagnostic Mode after 60 seconds
if no buttons are pressed.
Diagnostic Programming Mode Steps
1. Press the Up and Extra Cycle buttons for five seconds while
in service.
2. Press the Up button. Use this display to view the current
Flow Rate. This option setting is identified by “FR” in the
upper left hand corner of the screen.
3. Press the Up button. Use this display to view the Peak Flow
Rate since the last regeneration cycle. This option setting is
identified by “PF” in the upper left hand corner of the screen.
4. Press the Up button. Use this display to view the Hours
in Service since the last regeneration cycle. This option
setting is identified by “HR” in the upper left hand corner of
the screen.
5. Press the Up button. Use this display to view the Volume
Used since the last regeneration cycle. This option setting is
identified by “VU” in the upper left hand corner of the screen.
6. Press the Up button. Use this display to view the Reserve
Capacity. This option setting is identified by “RC” in the
upper left hand corner of the screen.
7. Press the Up button. Use this display to view the Software
Version. This option setting is identified by “SV” in the
upper left hand corner of the screen.
8. Press the Extra Cycle button to end Diagnostic
Programming Mode.
For Service Assembly Numbers, See the Back of this Manual