EasyManua.ls Logo

Pentair Goyen Precision P1 - P2 - Enhanced Demand Control

Pentair Goyen Precision P1
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 INSTALLATION AND OPERATING INSTRUCTIONS PRECISION
®
FILTER CLEANING SYSTEM CONTROLS
Tube Cleaner
Available on the AC/AC baseboard, otherwise only when P-CTX is fitted. This allows the tube-cleaning parameters to be
specified: Select ON or OFF, then:
Period: The frequency of the tube-cleaning pulse. 1 to 999 minutes.
Duration: The duration of the tube-cleaning pulse. 1 to 60 seconds. This feature is used to control the pulse cleaning of the
differential pressure-sensing lines. In the case of the P1 with P-CTX, these may be used to clear the pressure lines of third-party
pressure gauges installed on the dust collector.
Network
Allows the network address to be set for controllers running on a DCS. Values 0 to 255, and OFF. Setting to OFF takes the
Precision off the network.
Run
Returns the controller to operating mode.
P2 – ENHANCED DEMAND CONTROL
Menu Structure
LEVEL 1 ENTRY LEVEL 2 MENU ITEM LEVEL 3 SUB-MENU OPTIONS LEVEL 4 OPTIONS
1 Code
2
2a
2b
2c
2d
2e
Language
1
English
Italian
Spanish
German
French
3 Factory Defaults
1
4 On Time
1
5 Off Time
1
6
6a
6b
6c
6d
6e
Display Units
kPa
Pa
in WG
mm H
2
0
mm Hg
7
7a
7ai
7aii
7b
7bi
7bii
Demand Cleaning
Limits
Bandwidth
Low dP
High dP
High dP
Bandwidth %
8 Alarm Delay
9 High dP Alarm
10 Precoating
11 Pattern Cleaning
12 Blowdown Cycles
1
13
13a
13b
Remote Stop
Hardwired
Automatic
14
14a
14b
Tube Cleaner
1
*
Period
Duration
15 Maximum Interval
16 Hour Counter
1
17 Number of Slaves
1
18 Total Cycles
1
19 Network
1
**
20 Run
1
1
As described for the P1 interface.
* Available on the AC/AC baseboard, otherwise only when P-CTX is fitted.
** Only when P-MOD is fitted.

Related product manuals