10
L-1599 (04-01-22)
OPERATIONS & MAINTENANCE
WEAR PLATE
1. Inspect wear plate for excessive wear, surface grooves
or impeller contact. Replace if needed (Figure 15).
2. Remove two 3/8” stainless steel screws from wear ring
(Figure 16) .
Older models have acorn nuts and plastic washers on
the front of the pump. If equipped, remove these first
(Figure 17).
3. Install new wear ring, making sure pump surface and
ring are clean and the ring sits flat against the pump.
4. Reinstall stainless steel screws.
5. Reinstall plastic washers, and acorn nuts on older
models.
MECHANICAL SEAL
1. Remove seal and spring from impeller/drive sleeve
assembly (Figure 18).
2. Clean drive sleeve surface. Surface may be cleaned with
400 grit or higher sandpaper. If sleeve surface is worn,
grooved or pitted, replace drive sleeve.
Worn or damaged impeller/drive sleeve may cause the
pump to under perform or become unbalanced, causing
mechanical seal damage.
Careful attention must be taken as to not scratch or
damage the carbon face during installation.
3. Install new seal half onto drive sleeve.
4. Remove ceramic half from adapter flange.
5. Clean flange opening with a wire brush and/or
sandpaper. (Figure 19)
Careful attention must be taken as to not scratch or
damage the ceramic face during installation.
6. Apply light lubrication to the outer rubber cup of the
ceramic seal.
7. Install new seal half. Use your thumbs to apply light even
pressure to set the cup in the adapter pocket. (Figure
20)
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20