IntelliFlo Installation and Users Guide
4. Make sure all electrical connections are clean and tight.
5. Open the air release valve on the filter, and stand clear of the filter.
6. Switch the IntelliFlo on at the circuit breaker. Ensure that the green power LED is on.
7. Press the Manual button (LED on) to place IntelliFlo in manual mode.
8. Use the Up and Down arrows to select Set Speed, then press the Select button to edit the setting.
7. Adjust speed as necessary. Press the Left and Right arrows to select which digit to modify, then
use the Up and Down arrows to change the speed. Press the Enter button to save the changes. To
cancel any changes, press the Escape button to exit edit mode without saving.
9. Press the Start/Stop button to start the pump.
10. When water comes out of the air release valve, close the valve. The system should now be circulating water
back to the pool without air bubbles showing in either the hair and lint pot or at the pool return fittings.