P/N 472592 Rev. C 10-5-07
14
“RESIDENTIAL”
PROPANE
GAS 2 STAGE REGULATION
In many Propane gas line installations, the gas supplier and/or installer will utilize a two stage regulation process
where by at the supply tank they will install the first stage gas regulator, which would be at a higher pressure, usually
10 psi. This higher pressure allows for a much longer distance and in a much smaller pipe size. Then within a short
distance of the pool heater, usually around 24 inches, they will install a second regulator, which is the second stage,
and this would be set at the required inlet pressure of the heater.
See “Gas Pressure Requirement Charts”
Table 3.
Table 4.
GAS PIPE SIZING
Table 2.
“RESIDENTIAL”
NATURAL
GAS 2 STAGE REGULATION
In many Natural gas line installations, the gas supplier and/or installer may utilize a two stage regulation process
where by at the streets main gas supply they will install the first stage gas regulator, which would be at a higher
pressure. This higher pressure is usually set at 2 psi or 5 psi and can be for long distances and in a much smaller pipe
size. Then within a short distance of the pool heater, generally around 24 inches, they will install a second regulator,
which is the second stage. This second stage regulator would be set at the minimum operating pressure for the heater.
For “Natural Gas Pentair Pool Heaters” the minimum is 7 inches W.C.
See “Gas Pressure Requirement Charts”
Table 5.
Table 6.
Section 3. Installation
SNOITCENNOCENILSAGROFGNIZISEPIP
HTGNELEPIPTNELAVIUQEMUMIXAM
).tF(
tooFcibuCrep.U.T.B0001tasaGlarutaN
tooFcibuCrep.U.T.B0052tasaGenaporP
LEDOM
2/1 4/3 1 4/1-1 2/1-1 2 2/1-2
TAN ORP TAN ORP TAN ORP TAN ORP TAN ORP TAN ORP TAN ORP
571 - 02 03 08 521 052 054 006 - - - - - -
002 - 02 03 08 521 052 054 006 - - - - - -
052 - 01 02 05 07 051 052 005 006 - - - - -
003 - - 01 03
05 001 002 053 004 006 - - - -
004 - - - 01 02 06 001 051 002 054 004 - - -
gniziSepiPsaG"erusserPhgiH"enOegatS
.TF.UCreP.U.T.B0052@ISP01
HTGNELEPIPTNELAVIUQEMUMIXAM
ledoM .tF05ot0 .tF001ot05 .tF051ot001
004hguorht571 .ni2/1 .ni2/1 .ni2/1
gniziSepiPsaG"erusserPwoL"owTegatS
.C.W.ni41tates2egatS
HTGNELEPIPTNELAVIUQEMUMIXAM
ledoM .tF01ot0 .tF02ot01
004hguorht571 .ni4/3 .ni4/3
gniziSepiPsaG"erusserPhgiH"enOegatS
.TF.UCreP.U.T.B0001@ISP2
HTGNELEPIPTNELAVIUQEMUMIXAM
ledoM .tF05ot0 .tF001ot05 .tF051ot001
003hguorht571 .ni2/1 .ni2/1 .ni2/1
004 .ni4/3 .ni4/3 .ni4/3
.TF.UCreP.U.T.B0001@ISP5
004hguorht571 .ni2/1 .ni2/1 .ni2/1
gniziSepiPsaG"erusserPwoL"owTegatS
.C.W.ni7tates2egatS
HTGNELEPIPTNELAVIUQEMUMIXAM
ledoM .tF01ot0 .tF02ot01
003hguorht571 .ni4/3 .ni4/3
004 .ni4/3 .ni1
.C.W.ni7tates2egatS
004hguorht571 .ni4/3 .ni1

Table of Contents

Other manuals for Pentair MASTERTEMP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP and is the answer not in the manual?

Pentair MASTERTEMP Specifications

General IconGeneral
ModelMASTERTEMP
CategorySwimming Pool Heater
BrandPentair
BTU Ratings125, 000 - 400, 000 BTU/hr
Fuel TypeNatural Gas or Propane
DisplayDigital display
Water Flow Rate20-120 GPM
Efficiency82% (Thermal Efficiency)
IgnitionElectronic
Voltage120V or 240V
Operating Pressure50 PSI (Maximum)
Temperature Range104°F
DimensionsVaries by model
WeightVaries by model