Rev. C 10-5-07 P/N 472592
19
CAUTION
Chemicals should not be stored near the heater installation. Combustion air can be contaminated by corrosive
chemical fumes which can void the warranty.
Corrosive Vapors and Possible Causes
COMBUSTION AIR SUPPLY
For indoor installation, the heater location must provide
sufficient air supply for proper combustion and ventilation
of the surrounding area.
The minimum requirements for the air supply specify that
the room in which a heater is installed should be provided
with two permanent air supply openings; one within
12 inches (30cm) of the ceiling, the other within 12 inches
(30cm) of the floor for combustion air, in accordance with
the latest edition of ANSI Z223.1, or the National Fuel Gas
code, the CSA B149.1, Natural Gas and Propane Installation
Codes, as applicable, and any local codes that may apply..
These openings shall directly, or through duct, connect to
outdoor air.
Pentair Water Pool and Spa, Inc. does not recommend
indoor installations that do not provide combustion
air from outside the building.
Air Supply Requirements Guide
for MasterTemp Heaters
Section 3. Installation
Table 8.
Table 9.
*gninepOhcaErofaerAnepOeerFteNmuminiM
)sretemitneC/sehcnIerauqS(
ledoM
gnidliuBedisnImorFriAllA gnidliuBedistuOmorFriAllA
noitsubmoC tneV noitsubmoC tneV
571
.ni.qs002
.mc.qs0921
.ni.qs002
.mc.qs0921
.ni.qs05
.mc.qs323
.ni.qs05
.mc.qs323
002
.ni.qs002
.mc.qs0921
.ni.qs002
.mc.qs0921
.ni.qs05
.mc.qs323
.ni.qs05
.mc.qs323
052
.ni.qs052
.mc.qs3161
.ni.qs052
.mc.qs3161
.ni.qs36
.mc.qs604
.ni.qs36
.mc.qs604
003
.ni.qs003
.mc.qs5391
.ni.qs003
.mc.qs5391
.ni.qs57
.mc.qs484
.ni.qs57
.mc.qs484
004
.ni.qs004
.mc.qs0852
.ni.qs004
.mc.qs0852
.ni.qs001
.mc.qs546
.ni.qs001
.mc.qs546
*
.gniliecehttaenodnalevelroolftaeno;sgninepoowtfoenorofsidetacidniaerA
aerA stnanimatnoCylekiL
gnimmiwsdetanirolhC
sapsdnasloop
,sdicA.slacimehcgninaelcapsrolooP
.dicacitairumrocirolhcordyhsahcus
dnanoitcurtsnocweN
saeragniledomer
noitcurtsnoc,stnemecdnaseulG
tniapdna,sehsinrav,stniap,sevisehda
dnasexaW.sreppirtshsinravdna
muidosromuiclacgniniatnocsrenaelc
.edirolhc
srolrapytuaeB
,sehcaelb,snoitulosevawtnenamreP
snobracorolhcgniniatnocsnaclosorea
.snobracoroulfro
rostnalpnoitaregirfeR
gnihsiniflairtsudnisuoirav
stnalpgnissecorpdna
,stnemecdnaseulg,sdica,stnaregirfeR
.sevisehdanoitcurtsnoc
yrdnualdnagninaelcyrD
saera
spaosyrdnualro,stnegreted,sehcaelB
srenaelcdnasexaW.enirolhcgniniatnoc
muidosromuiclac,enirolhcgniniatnoc
.edirolhc

Table of Contents

Other manuals for Pentair MASTERTEMP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP and is the answer not in the manual?

Pentair MASTERTEMP Specifications

General IconGeneral
ModelMASTERTEMP
CategorySwimming Pool Heater
BrandPentair
BTU Ratings125, 000 - 400, 000 BTU/hr
Fuel TypeNatural Gas or Propane
DisplayDigital display
Water Flow Rate20-120 GPM
Efficiency82% (Thermal Efficiency)
IgnitionElectronic
Voltage120V or 240V
Operating Pressure50 PSI (Maximum)
Temperature Range104°F
DimensionsVaries by model
WeightVaries by model
WarrantyLimited Warranty