P/N 472592 Rev. C 10-5-07
40
Heater Will Not Fire - C
Start
Go to “INITIAL
TROUBLESHOOTING”
Continue to observe heater
for several minutes. Cycle
heater on and off several
times. Observe for delayed or
rough ignition, poor combus-
tion, premature extinction of
flame, evidence of boiling, or
operation of any diagnostic
LED. Go to pertinent trou-
bleshooting section if any
malfunction is
observed.
Replace Control Board.
Replace Gas Valve with
identical p
art.
Fix wiring between TH and
GND terminals of Ignition
Control Module and Control
Board.
Replace Control Board.
Fix wiring between GAS ter-
minals on Control Board and
Gas Va
lve.
NOTE 1: Voltage appears immedi-
ately after call for heat, and may be
on for only about 30 seconds.
NOTE 2: Voltage appears about 24
seconds after call for heat, and may
be on for only about 7 seconds.
Verify that gas supply is open
all the way to Gas Valve, and
Gas Valve is set at “on”
position.
Check for 24 VAC to Gas
Valve terminals during ignition
try. (Voltage appears about 24
seconds after call for heat).
SEE NOTE
2.
Turn off power to
heater for 5 seconds,
and turn back on.
Make sure tempera-
ture setting is above
water temperature.
Wait one minute.
Does heater fire and
stay
on?
Did Blower come on?
Verify that gas is flow-
ing to burner during
ignition try. Observe
gas meter for move-
ment during ignition
try (wait for about 30
seconds after calling
for
heat).
Check for 24 VAC
between TH and GND
terminals on Ignition
Control Module.
SEE NOTE
1.
Check for 24 VAC
between TH and GND
terminals on Control
Board. SEE NOTE
1.
Check for 24 VAC
between GAS termi-
nals on Control
Board. SEE NOTE
2.
Replace Control
Board.
NO
CONTINUE
YES
YES
YE
S
NO
NO
YES
NO
YE
S
NO
NO
YE
S
YE
S
NO
YE
S
YE
S
Is “SERVICE HEATER” LED
“on”?
Go to “BURNER
TROUBLESHOOTING”
(Page
44)
Go to “HEATER WILL NOT
FIRE-D” (Page 41)
Check for 24 VAC between
VAL and GND terminals on
Ignition Control Module.
SEE NOTE
2.
Check for 24 VAC between
VAL and GND terminals on
Control Board. SEE NOTE
2.
If any red diagnostic LED’s
(AGS, AFS, SFS, HLS, PS, or
THERMISTOR) come “on”, go
to to Pages 42 and
43.
Did burner fire at all?
Replace Ignition Control
Module.
NO
YES
Fix wiring between VAL and
GND terminals of Ignition
Control Module and Control
Board.
NO
YES
NO
NO
Section 5. Troubleshooting

Table of Contents

Other manuals for Pentair MASTERTEMP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP and is the answer not in the manual?

Pentair MASTERTEMP Specifications

General IconGeneral
ModelMASTERTEMP
CategorySwimming Pool Heater
BrandPentair
BTU Ratings125, 000 - 400, 000 BTU/hr
Fuel TypeNatural Gas or Propane
DisplayDigital display
Water Flow Rate20-120 GPM
Efficiency82% (Thermal Efficiency)
IgnitionElectronic
Voltage120V or 240V
Operating Pressure50 PSI (Maximum)
Temperature Range104°F
DimensionsVaries by model
WeightVaries by model
WarrantyLimited Warranty

Related product manuals