MicroBrite Color and White Light Installation and User’s Guide
6
Be sure the electrical system of your pool conforms with the following requirements
of the Canadian Electrical Code (CE), and all local codes and ordinances. A licensed
or certified electrician must install the electrical system to meet or exceed those
requirements before the light and (fixture-housing) is installed. Some of the CE
requirements are listed below.
• The junction/deck box must be sealed to the conduit to prevent water from
getting into the box, see Figure 2, below.
MICROBRITE™ COLOR AND WHITE LED LIGHT
INSTALLATION IN 1.5” WALL FITTING CANADA
The following information is for the Junction Box and pool deck location for Canada only.
Junction/Deck boxes shall be installed:
(a) above the normal water level of the pool;
(b) so that the top of the box is located at or above the finished level of the pool deck;
(c) in such a manner or location that the box will not be an obstacle; and
(d) in such a manner that any water on the deck will drain away from the box
(See diagram below).
Deck water drains
away from Junction/Deck Box
Approved Junction/Deck Box
Water level
below Junction/Deck Box
Approved Junction/Deck Box
elevated and protected
Diving Board or
other equipment
to protect
Junction/Deck Box