MiniMax Plus Troubleshooting/Check List
1. Look at the lights/which ones are on?
2. Check for correct voltage on both sides of the transformer.
3. Check Ignition wire connections on the module and the pilot ignitor.
4. Check position of pilot to the burner and check the components for correct spacing.
5. Check the wire harness and wire connections to the circuit board.
6. Check for true ground and good ground connections.
7. Push the Pool/Spa switch “ON” and turn Pots Cold to Hot.
8. Make sure the Pump is running and is primed.
9. Remove any Remote Control wires from the heater circuit board and replace the jumper wire
while testing.
IGN RETURN (GRN)
WHT
PACFAB 6800
THERMOSTAT
ELECTRONIC
DUAL
THERMISTOR PROBE
ON / OFF / ON
SWITCH
(WHT)
SPA
(WHT)
POOL (WHT)
COMMON
WHT
WHT
WHT
THERMAL FUSE
ORN
WHT
RED
ORN
BLK
J BOX
GRN
ORN
WHT
RED
BLUE
WHT
BLUE
RED
CHASSIS SHEET METAL
TRANSFORMER
RED
WHT
PRESSURE
SWITCH
WHT
GAS VALVE
IID
RED
RED
RED
RED
WHT
IGNITION
MODULE
BLUE
GRN
HILIMITS
HI TENSION
WIRE
IID PILOT
WHT/BLK
WHT/RED
JUMPER
(WHT)
  
The wiring was crossed from
the Switch to the Board and
we used a Breaker (Reset)
that was external to the
Transformer.
Troubleshooting