8.2.8 Admissible Parameters
Bild 8.28: Structure of the "Read head-no." nibble and the "Head-no" byte
Bild 8.29: Structure of the head status nibble when no errors detected
Bild 8.30: Structure of the head status nibble when no errors detected
Bild 8.31: Valid start addresses (Data Start 1 and Data Start 2) for read/write commands for
the various data carrier types.
Bild 8.32: Valid number of data bytes for read/write commands for the various data carrier types
Head number Hex identifier
Nibble Byte
111
222
333
444
X55
BIT Read-head
01
12
23
3 4
Data carrier type Page number
IDC- ... ----------------
IDC - ... -1K 000 ... 003h
IMC-40-64K 000 ... 0FFh
IMC-40-256K 000 ... 3FFh
Data carrier type Address
IDC- ... 0000 ... 001Fh
IDC - ... -1K 0000 ... 007Fh
IMC-40-64K 0000 ... 1FFFh
IMC-40-256K 0000 ... 7FFFh
Data carrier type Quantity
IDC- ... 01 ... 20h
IDC- ... -1K 01 ... 80h
IMC-40-64K 01 ... 80h
IMC-40-256K 01 ... 80h