EasyManua.ls Logo

Perkins 854F-E34T - Overspeed; Overspeed Detection

Perkins 854F-E34T
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
For information on the operation of the warning lamps
and the shutdown lamp, refer to this Operation and
Maintenance Manual, “Monitoring System (Table for
Indicator Lamps)”. For each of the programmed
modes, refer to Troubleshooting Guide, “Indicator
Lamps” for more information on Indicator Lamps.
For more information or assistance for repairs,
consult your Perkins distributor or your Perkins
dealer.
i04348489
Overspeed
ECM Electronic Control Module
RPM Revolutions Per Minute
An overspeed is
detected by the speed/timing
sensors.
The default overspeed is set at 2800. The ECM will
cut the power to the electronic unit injectors, until the
rpm drops below the overspeed setting. A diagnostic
fault code will be logged into the ECM memory and a
warning lamp will indicate a diagnostic fault code.
Some application may have a display panel in order
to alert the operator.
36 SEBU8726
Features and Controls
Overspeed

Table of Contents

Other manuals for Perkins 854F-E34T

Related product manuals