Table 12
World-Wide DEF Level Option 2
-
Normal operation Initial indication Level 1 Level 2 Level 3
Inducement Trigger Above 19 percent Below 19 percent Below 12.5 percent 6 Percent reading 0 Percent reading
Inducement None None None None The engine may be
derated by 50 percent
torque
A shutdown or low
idle only will be en-
forced after 5
minutes.
Notification None Low-level lamp
illuminated
Low-level lamp
illuminated
Emission malfunction
lamp on solid
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Stop lamp on solid
M0092609-05 71
Operation Section
Selective Catalytic Reduction Warning System

Table of Contents