iMETOS Maintenance & troubleshooting 8
6. SOIL TEMPERATURE SENSOR
6.1 Maintenance
The soil temperature sensor does not need any maintenance. If it fails it is nearly always due to damaged wires.
6.2 Troubleshooting
Sensor shows values out of range: water entered in the sensor – sensor should be replaced.
Gap of data: cable might be damaged, this increases power consumption and it can lead to misfunction on
the station – unplug the sensor and replace it.
7. GLOBAL RADIATION SENSOR
7.1 Maintenance
The global radiation sensor should be maintained cleaned. A visible check at the plastic cover is recommend-
ed at the beginning of the season.
7.2 Troubleshooting
Values out of range (higher/lower than expected): check sensor status, cleaning, orientation.
Values dierent to 0 at night: water enters in the sensor, exchange the sensor.
No values: cable cut.
8. WIND SPEED AND DIRECTION SENSOR
PI Wind Speed Sensor (IM512CD)
Maintenance
The wind sensor should be examined whether the wind wheel is low-friction. Check for easy-going and the
sound. If it is not the case, send the sensor for service to us. If the wind wheel is damaged please order a new
one.
Troubleshooting
Heavily increment of values – replace the main board.
Check for induction (cable rounded around the pole): cable should be positioned along the pole, but not
wrapped around it.
Station gets frequent reset – power cable or pcb are damaged.

Related product manuals