iMETOS Maintenance & troubleshooting 9
• Reduced values – mechanical problem of the sensor.
• No value: cable is damaged.
PI Wind Direction (IM511CDI)
Troubleshooting
• No values: internal battery should be replaced/cable is damaged.
RM Young (05103L)
Troubleshooting
• No values: internal battery should be replaced, lifetime of the battery is highly inuenced by the frequency
of heavy wind.
Ultrasonic Atmos 22/D2
Troubleshooting
• No values: check that interface board is properly mounted.
PI Ultrasonic (PI-USWM)
Maintenance
Clean the outer surfaces of the sensor with wet map water or neutral soap once per season and every time it
receives signicant amounts of dust or phytosanitary spray.
Troubleshooting
If the sensor requires a software update (all units before DEC 2019), this request will be attended by Pessl
Instruments after-sales service.
9. PI-Bus
Troubleshooting
• No data at all: cable cut/old, dierent sensor timing, water entered in the box.
• No sensor data: sensor cable cut, water entered in the sensor.
10. RADIONODE TROUBLESHOOTING
10.1 Reset the WSN
• Reset the RF AP board: by power up push the button and hold the button at least 2 seconds. The all 3
LED diodes will be ashing for 2 seconds. All conguration and link settings of the wireless system will be
erased in RF AP board.