Correct
setting:
Scale
ring
in
reverse-feed
control
With the stitch length
set
at
"0",
the
"0"
mark on scale ring 3 should be opposite
mark
4.
1.0.1
1.1
Take
the
needles
out
of
the
needle
holder.
1.2
Remove
the
knee
levertogether with its coupling
sleeve.
1.3
Tum
knurled
disc
1
as
far
as
it will
go
in
the
direction in which
the
reverse-feed
control
starts
to
move
downwards.
1.4
Loosen
screw
2
and
turn
scale
ring
3 until
the
"0"
mark
Is
opposite
mark
4.
1.5
In this position, tighten
screw
2.