Adjustment
11 - 55
11
.07.08 Releasing the tension
Requirement
When the magnet is activated, tension discs 3 must be at least 0.5 mm apart.
Fig. 13 - 51
● Activate the magnet.
● Detach the tension bearing plate 1 and adjust pressure plate 2 in accordance with the
requirement.
It is possible to set the time for releasing the tension with the parameter
functions, see Chapter 11.10 Parameter settings.
61-043
1
2
3
0.5 mm