EasyManuals Logo

Pfaff Powerline 2545 User Manual

Pfaff Powerline 2545
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
Controls
Key 3: Needle position change
This button can have the following functions assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L PF 321
Parameter Function Parameter Function
695
0 = Off
1 = needle raised without trimming
2 = needle position change (standard)
3 = single stitch
4 = single stitch in reverse
5 = moving forwards to needle
position step by step
6 = programmable tack on / off
842
0 = Function off
01 = Needle up without trimming
02 = Change needle position (standard)
03 = Single stitch
20 = Step-by-step approach to a
needle position forward
95 = Offset multi-backtack
96 = Backtack suppression (all autom.
backtack deactivated)
97 = Single stitch reverse
98 = Not used
Key 4: Calling up the pre-selected top feed lift.
(Diode on = high lift, diode off = low lift)..
This button can have the following functions assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L PF 321
Parameter Function Parameter Function
401
0 = Off
1 = when key pressed constant
second stroke (standard)
2 = second stroke only as long as key
pressed
If this key is operated, the second
voltage is switched on
This function can be switched off un-
der Parameter 764
843
0 = Off
01 =
With button pressed constantly,
2nd lift (standard)
02 = 2nd lift only while button is
pressed
14 = Stroke adjustment (Flip Flop 1)
with speed limit N10
(Parameter 137 must be set to "On"
Key 5: Bartack suppression for one bartack.
This button can have the following functions assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L PF 321
Parameter Function Parameter Function
780
0 = Off
1 = tack inversion once (standard)
2 = tack suppression (all tacks
switched off)
3 = reverse move to needle position
step by step
4 = edge trimmer on / off
5 = programmable tack on / off
844
17 = Backtack inversion, single
(standard)
21 = Step-by-step approach to a
needle position reverse
95 = Offset multi-backtack
96 = Backtack suppression
(all autom. backtack deactivated)
97 = Single stitch reverse
98 = Not used

Table of Contents

Other manuals for Pfaff Powerline 2545