EasyManua.ls Logo

Phantom Laboratory Catphan 503 User Manual

Phantom Laboratory Catphan 503
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
T h e P h a n t o m L a b o r a t o r y
C a t p h a n ® 503 M a n u a l
Copyright © 2017
WARRANTY
THE PHANTOM LABORATORY INCORPORATED (“Seller”) warrants that this product
shall remain in good working order and free of all material defects for a period of one
(1) year following the date of purchase. If, prior to the expiration of the one (1) year
warranty period, the product becomes defective, Buyer shall return the product to the
Seller at:
By Truck By Mail
The Phantom Laboratory, Incorporated The Phantom Laboratory, Incorporated
2727 State Route 29 PO Box 511
Greenwich, NY12834 Salem, NY 12865-0511
Seller shall, at Seller’s sole option, repair or replace the defective product. The Warranty
does not cover damage to the product resulting from accident or misuse.
IF THE PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED, THE
SOLE AND EXCLUSIVE REMEDY SHALL BE REPAIR OR REPLACEMENT,
AT SELLER’S OPTION. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY
DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT. THIS
LIMITATION APPLIES TO DAMAGES OF ANY KIND, INCLUDING, BUT NOT
LIMITED TO, DIRECT OR INDIRECT DAMAGES, LOST PROFITS, OR OTHER
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER FOR
BREACH OF CONTRACT, TORT OR OTHERWISE, OR WHETHER ARISING OUT
OF THE USE OF OR INABILITY TO USE THE PRODUCT. ALL OTHER EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTY OF MERCHANT ABILITY AND FITNESS FOR PARTICULAR PURPOSE,
ARE HEREBY DISCLAIMED.
WARNING
This product has an FH3-4 mm/min ame rating and is considered to be ammable. It is
advised not to expose this product to open ame or high temperature (over 125° Celsius
or 250° Fahrenheit) heating elements.
CTP503
1/12/17
Question and Answer IconNeed help?

Do you have a question about the Phantom Laboratory Catphan 503 and is the answer not in the manual?

Phantom Laboratory Catphan 503 Specifications

General IconGeneral
BrandPhantom Laboratory
ModelCatphan 503
CategoryLaboratory Equipment
LanguageEnglish

Summary

Catphan 503 Warranty Information

Introduction and Phantom Setup

Introduction to the Catphan 503 Manual

Manual's purpose, development, and overview of phantom modules.

Initial Phantom Positioning

Detailed steps for mounting and leveling the Catphan phantom in the CT scanner.

Phantom Position Verification

Methods to check X, Y, and Z axis alignment using scan images of the CTP404 module.

Incremental Phantom Module Positioning

Indexing distances from CTP404 to other test modules like CTP528 and CTP486.

Illustration of Catphan 503 Model

Diagram showing the arrangement of CTP404, CTP528, and CTP486 modules.

CT Module Tests and Procedures

CTP404 Module: Slice Width, Sensitometry, Pixel Size

Details the CTP404 module's components for slice width, sensitometry, and pixel size tests.

Patient Alignment System Check

Procedures to verify the accuracy of the CT scanner's laser, optical, and mechanical alignment.

Scan Slice Geometry (Slice Width) Measurement

How to measure slice width using the 23° wire ramps and FWHM calculation.

Scan Incrementation Accuracy Test

Testing scanner incrementation between slices using wire ramps and table movement.

Circular Symmetry and Spatial Linearity

Tests for circular symmetry and verification of spatial linearity of pixel size.

Spherical Acrylic Contrast Targets

Using spheres in the CTP404 module to evaluate imaging of volume averaged spheres.

CT or Hounsfield Numbers Explained

Discussion on CT number variability and linearity scale for CT scanners.

Sensitometry (CT Number Linearity)

Using sensitometry targets to monitor scanner performance and CT number linearity.

CTP528 High Resolution Module and Point Source

Details the CTP528 module for high resolution and the use of bead point sources.

Point Spread Function (PSF) and Modulation Transfer Function (MTF)

Methods for calculating PSF and MTF using impulse sources and image data.

Automated Scanner MTF Programs

Guidance on using automated software for MTF analysis with Catphan bead images.

Bead Point Source for Slice Sensitivity Profile (SSP)

Using the bead to calculate the slice sensitivity profile (SSP) using FWHM.

21 Line Pair per Centimeter High Resolution Gauge

Resolution tests using the 21 line pair/cm gauge for visual evaluation.

CTP486 Image Uniformity Module

Module for measuring spatial uniformity, mean CT number, and noise value.

Installation and Removal of Test Modules

Step-by-step instructions for removing and inserting modules into the Catphan housing.

Optional Phantom Annuli

Description of optional annuli designed to be used with the standard 20cm Catphan housing.

Dose Phantoms

Information on CTP553 and CTP554 dose phantoms and their mounting procedures.

Quality Assurance and Computer Analysis

Sample Quality Assurance Program

A sample QA program outlining suggested frequencies for various CT tests.

Automated Computer Analysis Program

Details web-based automated CT performance testing services like Image Owl.

Bibliography